Questions and Answers

  • J
    John CharlesAug 18, 2025
    Why is my Hardy H5 Wood stove using excessive wood or overheating?
    • M
      Matthew BurgessAug 18, 2025
      Excessive wood usage or overheating in your Hardy Wood stove can be caused by several factors. Make sure all doors are closed and securely fastened, and inspect door seals for damage, replacing them if necessary. Also, check the damper blower lid for any obstructions, such as creosote buildup; if found, unplug the blower motor, disassemble, clean, and oil it. Ensure the damper aquastat is set to 170ºF, and replace it if it's causing the blower to run until the water boils. Finally, inspect all water lines and connections for leaks, repairing or replacing any that are found.
  • L
    lawsonconnieAug 20, 2025
    What to do if my Hardy H5 is using excessive wood or overheating?
    • T
      Taylor AndersonAug 21, 2025
      If your Hardy Wood stove is using excessive wood or overheating, several issues could be the cause. Check the pop-off valve and replace it if it's relieving for no apparent reason. Inspect the liquid level switch float to ensure it's upright, with the magnets on top; if the solenoid doesn't click and the light doesn't turn on and off when moving the float, replace the switch. If the solenoid clicks but the heater still overflows, it may be stuck open; remove and clean or replace it. Disconnect the line to the electric water solenoid and turn off the valve to the system fill to ensure no water enters the tank from the fill system. If the heater tank still overfills, remove the heater hull and lid to check the domestic water coil for leaks; repair or replace as needed.
  • B
    Barry SchultzAug 23, 2025
    What to do if water is not circulating through the heat loop in my Hardy Wood stove?
    • J
      Jennifer ReyesAug 23, 2025
      If water isn't circulating through the heat loop in your Hardy Wood stove, several factors could be responsible. Check that the pump is operating correctly. Ensure that any inline valves are open and functioning. Bleed the lines to remove any trapped air; note that non-pressurized lines require the pump to be running during bleeding. If there are scale deposits in the hot water coil, disconnect the inlet and outlet and clean the coil with a descale cleaning kit. Also, bleed any air from the hot water coil.
  • A
    Anthony HallAug 27, 2025
    Why is the pump not running in my Hardy Wood stove?
    • C
      Cassandra Schneider DVMAug 28, 2025
      If the pump in your Hardy Wood stove isn't running, here's what you can check: First, unplug the pump, remove it, and pull the cartridge from the pump. Spin the impeller by hand; if it won't spin, replace the cartridge. Next, use an ohmmeter to test the capacitor; when connected, the needle should jump towards “0” ohms and slowly drift back to infinity; replace the capacitor if it's defective. Finally, disconnect the wires connected to the motor terminals to test the motor independently; check for ground and continuity with an ohmmeter and ensure the windings' insulator shows no breakage; if it does, replace the pump.
  • P
    phillipcampbellAug 30, 2025
    How to clean ash bin for Hardy Wood stove?
    • M
      markgutierrezAug 30, 2025
      To maintain your Hardy Wood stove, clean out the ash bin weekly. Ash buildup on the grates can cause them to warp. If the grates warp, they can be turned over to straighten. When removing ashes, leave at least 1/2” to 1” of ashes in the bottom of the ash pan.
  • D
    davidjordanSep 1, 2025
    What to do if my Hardy H5 has improper burning?
    • N
      Norma SmithSep 1, 2025
      If your Hardy Wood stove is burning improperly, the grates may be stopped up. Clear the grates of ash buildup. If the grates are warped, turn them over.
  • H
    hayeskennethSep 3, 2025
    What to do if my Hardy Wood stove's water solenoid valve is defective?
    • J
      Juan MartinezSep 3, 2025
      If the water solenoid valve does not click when checking the liquid level switch, but the level indicator light does come on, replace the solenoid valve. Also, remove the filter screen from the 1/2” bushing in the end of the 1/2” ball valve and clean or replace it.
  • L
    Lawrence CarrSep 6, 2025
    What to do if my Hardy H5 Wood stove has a forced air blower running but no draft?
    • L
      Lisa PhillipsSep 6, 2025
      If the forced air blower is running but there is no draft, the solenoid may not be lifting the lid. If so, replace the solenoid. Creosote buildup may also be the cause. Please refer to the section on excessive wood usage.
  • R
    Rita AndersonSep 8, 2025
    What to do if there is moisture in the fire box of my Hardy H5 Wood stove?
    • A
      Anne KingSep 8, 2025
      If you notice moisture in the firebox of your Hardy Wood stove, it could be due to a couple of reasons. During the initial or yearly start-up, the firebox walls might sweat, causing water to run down the sides; this should clear up within about a week. Alternatively, using green wood can also create moisture at any time.
  • D
    David AlexanderSep 12, 2025
    What to do if the air tube is clogged in my Hardy Wood stove?
    • J
      Jason SmithSep 12, 2025
      If the air tube in your Hardy Wood stove is clogged, lift the inspection lid and clean out all obstructions.

Summary

Safety Precautions

General Safety Warnings

Essential safety precautions to protect users from potential injury during operation.

Outdoor Furnace Best Burn Practices

Section II Installation of Heater

Heater Location and Pad Setup

Guidance on selecting the optimal location and preparing the concrete pad.

Underground Line Installation

Details on trenching and running water and electrical lines underground.

Connecting Electrical Power

Step-by-step instructions for safely connecting electrical power to the heater.

Plumbing to Heating System

Instructions for connecting the heater to the heating system via plumbing.

Section III Connection to Central Heating;AC System

Central HVAC System Connection

Detailed wiring and connection steps for integrating with a central HVAC system.

Section IV Connection to Hydronic Heating Systems (Baseboard)

Hydronic System Wiring

Wiring and connection instructions for hydronic systems using a 24V transformer.

Section V Plumbing Options for Domestic Hot Water

Section VI Heater Operation

Section VII Service Information

Troubleshooting Guide

Comprehensive guide to identify and resolve common heater problems.

Hardy H5 Specifications

General IconGeneral
BrandHardy
ModelH5
CategoryWood stove
LanguageEnglish