EasyManua.ls Logo

Harman Kardon HKTS 200 SUB - Page 4

Harman Kardon HKTS 200 SUB
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Paramete
r
S
p
ecification Unit QA Test Limits Test Conditions, Notes, and Comments
Power suppl
y
Type SMPS - -
Half bridge, with auxiliary fly back standby supply.
1/2 rated power continuous, and rated power for > 1 Minute, 25 degree ambient, rated
resistive load measured on bench to
p.
Voltage Range
220-240 or 100-
120
Vac 190 & 264
IQC to test power supply at 264 V, 50 Hz input voltage, shall operate at +/- 10 % of the rate
d
values
O
p
eratin
g
fre
q
uenc
y
50-60 Hz -
Efficienc
y
>80% - - At rated
p
ower out
p
u
t
Detachable AC
p
ower cord No - - Fixed Euro Plu
g
for 220-240 V units, and fixed US
p
lu
g
for 100-120 V units
Standb
y
p
ower dra
w
<0.5 W -
ATO / Trigger Truth Tabl
e
Trigger Jack Sense
Trigger Input
State
Power
Mode
SW
Input Signal
Sense
System State
(1=jack, 0=no jack)
(1 = high,
0=low
)
(1=ON,
0=Auto
)
(1=signal, 0=no
si
g
nal
)
11
x
x
On
10
x
x
Of
f
0
x
1
x
On
0
x
01 On
0
x
00 Of
f