# 8 Installing through the ceiling
Through the ceiling vent, follow PL vent manufacturers
recommendations when using wall and ceiling pass through. Note:
Do not place j oints within wall pass-throughs.
F ig. 1 4
PL vent manufacturer's
restop spacer and support
(See Page 7 for
corner installation
clearances)
nmum ue ent cnuratn
It is recommended that outside
air be installed with this venting
configuration to reduce smoke
and creosote smell in the room in
the event of power failure.
Min. above ground level
12
Storm collar
Flashing
 min.
 min.
12 min.
 min.
V enting
F ig. 1 5
 min.
No insulation or
other combustible
materials are
allowed within
3" of the pellet
vent pipe. Unless
specied by the
pipe manufacturer
F ig. 1 6
12"
min. wall to outlet
36"
min. clearance to any
combustable material