# 8 Installing through the ceiling
Through the ceiling vent, follow PL vent manufacturers
recommendations when using wall and ceiling pass through. Note:
Do not place j oints within wall pass-throughs.
F ig. 1 4
PL vent manufacturer's
restop spacer and support
(See Page 7 for
corner installation
clearances)
nmum ue ent cnuratn
It is recommended that outside
air be installed with this venting
configuration to reduce smoke
and creosote smell in the room in
the event of power failure.
Min. above ground level
12
Storm collar
Flashing
min.
min.
12 min.
min.
V enting
F ig. 1 5
min.
No insulation or
other combustible
materials are
allowed within
3" of the pellet
vent pipe. Unless
specied by the
pipe manufacturer
F ig. 1 6
12"
min. wall to outlet
36"
min. clearance to any
combustable material