EasyManua.ls Logo

Harman P61A - Automatic Operation

Harman P61A
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18P 6 1 A P ellet S tove
3 -9 0 -0 5 8 2 2 R 2 8 _ 0 8 /1 3
The P1A Pellet Stove is capable of manual operation. This also allows the operator to manually
control operation during an emergency (i.e. igniter failure, when using a 502H battery backup,
as opposed to the 512H, or when using certain generators.)
The unit can be switched between AUTO and ANUAL at any time during operation.
Igniter Switch to " MANUAL"
R oom Temperature Mode
The re will have to be lit with starting gel and a match, or
started automatically, see Automatic Operation on Page 1.
Turn to anual position when the ignition cycle has started.
The difference between AUTO Room Temperature ode
and anual Room Temperature ode is that the re will
not go out as the room temperature goes above the control
board setting. The unit can only go to low burn and will remain
there until it runs out of fuel or until more heat is needed
and the feed rate increases. eed rate adustments and dial
settings are the same as AUTO settings. The blower will
shut off completely if the temperature on the ESP is too low.
Igniter Switch to " MANUAL"
Stove Temperature Mode
The advantage of this mode is to allow the operator to have
a large viewing re without blowing extra heat into the room.
uring operation, with the temperature dial set at #5 or less,
the distribution fan will not operate. A #5 on the temperature
dial and a #5 on the feed aduster is approximately 80
output. It is not necessary to operate the distribution blower
below this point. This control setting allows a higher burn rate
(a larger viewing re) without an excess of hot air blowing
into the room.
An example of when to use the anual Stove Temperature
ode is if you want to watch a large re and the room is
already up to temperature. The Stove Temperature ode
allows you to have a larger re and a lower sound level,
without the distribution blower.
NOTE: During the use of this mode, if you keep increasing
te temperature a ettn t ncreae te re e te
distribution blower will automatically come on when the
ESP Temperature reaches 3 5 0
o
F , or 8 1 % output.
NOTE: W hen starting the unit in the " AUTO" mode and
switching to " MANUAL" , the ignition cycle must be
allowed to begin prior to making the switch.
MANUAL IG NITION/ OPER ATION
This setting will produce a large viewing re without a
distribution blower operating.
Manual Stove Temperature Mode
Room Temperature Mode: This
setting, see below, will produce a
room temperature of 70 degrees
with the distribution blower at
medium speed.

Related product manuals