9 pC 45 Corn/pellet Stove
3-90-02686R29_05/14
Fig. 11
Fig. 12
Venting
#3 Installing into an existing chimney
Thismethodprovidesexcellentventingfornormaloperation.
This method also provides natural draft in the event of a
powerfailure.Ifthechimneyconditionisquestionableyou
maywanttoinstallalinerasinmethod#6.Checkwithyour
local regulations, some municipalities require a complete
liner.
Chimney must be of a type suitable for solid fuel
burning.
Chimney and connector must be maintained in good
condition and kept clean.
#4 Installing into an existing replace chimney
Thismethodprovidesexcellentventingfornormaloperation.
This method also provides natural draft in the event of a
powerfailure.
Thedamperareamustbesealedwithasteelplate.Kaowool,
mineralwooloranequivalentnon-combustibleinsulationis
recommendedtobeinstalledontopofthesealingplateto
reducethepossibilityofcondensation.Theconnectorpipe
shouldextendthroughthesmokechambertothebaseorinto
therstuetile.Acapshouldbeinstalledonthechimneyto
keepoutrain.Ifthechimneyconditionisquestionableyou
maywanttoinstallalinerallthewaytothetopasinmethod
#5.Checkwithyourlocalregulations,somemunicipalities
requireacompleteliner.
Chimney must be of a type suitable for solid fuel burning.
Chimney and connector must be maintained in good
condition and kept clean.