5
XXV Pellet Stove
Installing 
Place the stove on a non-combustible oor
protector that extends a minimum of 6 inches 
tothefront,2inchestothesidesandushwith
the rear of the hopper. Ash protection must also 
be positioned under any horizontally run ue
pipe.Theminimumoorprotectormaterialis20
gaugesheetmetal.Otheroorprotectormateri-
als are ceramic tile, stone, brick, etc.
Place the stove away from combustible walls 
at least as far as shown in Figures 2, 3 and 4. 
Note that the clearances shown are minimum 
for safety but do not leave much room for access 
when cleaning or servicing. Please take this into 
account when placing the stove. 
Connect the power cord to a 120 V.A.C. 60Hz 
grounded receptacle. (A surge protector is recommended to 
protect the circuit board.) If the voltage entering your home 
is below 116 volts your stove may not work properly.  Also be 
sure that the polarity of the outlet that the stove is plugged 
into is correct.
Priortoinstallingtheuepipe,connectadraftmeter.(The
draft meter must have a minimum range of 0-.5.)Record the 
rstreading.Connectuepipetostoveandbesurealldoors
and windows in the home are closed.  Record the second 
draft reading_______.  If the second reading is more than .05" 
lowerthantherstreading,checkforpossiblerestrictionsor
the need for outside air (see page 8). For more information 
on the draft test procedure, refer to Page 20.
Mobile Home Installation
When installing this unit  in a mobile home several re-
quirements must be followed 
(Reference HUD Regulation 
#24CFR3280)
: 
1.Theunitmustbeboltedtotheoor.Thiscanbedoneby
using clips (part # 2-0-677110) and 1/4" lag screws.
2. The unit must also be connected to outside air. See 
page 8.
3. Floor protection and clearances must be followed as 
shown.
4. Unit must be grounded to the metal frame of the mobile 
home.
CAUTION: This appliance must be vented to the out-
side.
4" from 
back of top 
ueventto
wall
18" 
Fig. 5: Optional Top Vent Pipe Clearances 
Fig. 2
6.25"
6.25"
Installation
Fig. 3
12"
3"
Floor Protection must be 2 inches to each side, 6 
inches to the front, and 0 inches to the back of the 
stove. Floor Protector  minimum: 32" wide x 32" 
deep.
Fig. 4
0" 
32" minimum
32 minimum
2" from 
side of 
stove to 
combustible  
surface
6" from 
glass 
6"  from 
pipe to wall
Mobile home regulations do not allow 
installation in a room designated for 
sleeping.
WARNING
CAUTION 
THE STRUCTURAL INTEGRITY OF THE 
MOBILE HOME FLOOR, WALL, AND 
CEILING/ROOF MUST BE MAINTAINED.