SECTION I
OPERATION
1-1
.
INTRODUCTION
1-2.
The
information
contained
in
this
section
is
intended
to
familiariz
e
the
operator
with
the
preoperational
setup
and
the
operating
procedures
for
the
transmitter,
A
thorough
.
study
of
the
controls
and
indicators
is
recom-
mended
prior
to
turn-on
and
operation.
This
section
also
contains
tabular
data
on
the
function
of
each
control
and
indicator
with
reference
illustra-
tions
showing
their
location.
1-3.
The
preoperational
checkout
and
setup,
operati
ng
procedures
for
turn-
on
and
turn-off,
and
emergency
procedures
are
described.
1-4.
PERSONNEL
PROTECTION
1-5.
Extensive
interlocking
and
safety
switches
have
been
provided
on
these
transmitters
because
of
the
low
impedance
high
current
capabilities
of
the
power
supplies.
The
access
doors
to
th
e
transmitters
are
provided
with
three
safety
switches.
The
first
safety
switch
is
operated
by
a
small
pin
protruding
through
a
hole
and,
upon
opening
the
door,
interrupts
the
co
ntrol
voltage
to
the
prima
ry
contactors
allowing
them
to
deenergize.
Upon
opening
the
door
further,
a
large
switch
with
heavy
silver
contacts
is
provided
t o
discharge
the
energy
storage
capacitors
through
large
resistors
for
current
limiting.
Upon
opening
the
door
further
a
switch
operated
also
by
the
door
shorts
the
power
supply
to
the
cabinet
eliminating
any
possible
voltage
re-
maining
on
the
filter
capacitors.
WARNING
I
THE
NORMAL
PROCEDURE
IN TRANSMIT-
TER
TURN
OFF
SHOULD
BE
FOLLOWED
IN
DEENERGIZING THIS
TRANSMITTER.
TURN
OFF
THE
HIGH
VOLTAGE
BY
DE-
PRESSING
THE
OFF
BUTTON.
IF
YOU
MUST
ENTER
THE
TRANSMITTER,
ALLOW
THE
POWER
SUPPLY
TO
DISCHARGE
AS
INDICATED
BY
THE
FRONT
PANEL
METERS
.
DISCONNECT
PRIMARY
POWER
SERVICE.
OPEN
THE
DOOR
SLOWLY
TO
ALLOW
THE
INITIAL
RESISTOR
DIS-
CHARGE
MECHANISM
TO
FUNCTION.
UP-
ON
OPENING
THE
DOOR
FURTHER
THE
POWER
SUPPLY
WILL
BE
SHORTED
TO
GROUND
AND
MADE
SAFE. A
GROUNDING
STICK
IS
PROVIDED
IN
THE
TRANSMIT-
T
ER
AND
SHOULD
BE
USED
TO
ASSURE
THAT
ALL
VOLTAGE HAS
BEEN
REMOVED
UNDER
FAULT
CONDITIONS.
888-2125-001
WARNING:
Disconnect
primary
power
prior
to
servicing.
1-1