59
14. Adding Fuel / Heating at Nominal Thermal Output
More fuel should be added to the re when the ames from
the previous burning off phase have just gone out.
16. Banking the Fire and Raising the Temperature
Keep the stove set as described above until the brown coal
briquettes are thoroughly burnt. Then close the primary air (I)
and the re grate. Slide the secondary air slider (II) to position
2/3.
NOTE!
While the stove is in operation, the secondary
air slider should never be completely closed.
To raise the temperature of the re, stir up the rest of the
glowing embers with the re grate slider. Open the primary air
(I) and add new logs to the re.
17. Heating at Low Thermal Output
(during Transitional Seasons)
You can vary the thermal output of your Como by adjusting
the quantity of fuel used.
NOTE!
Do not attempt to slow down the combustion
by reducing the air supply. When heating with
wood, this can result in an incomplete burning
process and pose the risk of an explosive-like
combustion of the accumulated wood gases
(defl agration)
15. Heating with Brown Coal Briquettes
Wood should be used for the warming-up phase and when
adding fuel for the fi rst time, see “Warming-up Phase”. As
soon as a basic glowing fi rebed is reached, place 2-3 brown
coal briquettes on the grate in the middle of the fi rebox, kee-
ping a fi nger’s width between the briquettes, and use the
following procedure and settings:
Adding Fuel / Heating at Nominal Output
Procedure Position of
Control Elements
Adjust primary and
secondary air.
Close primary air slider
(I), set secondary air slider
(II) between position
2 and 3. (fi g. 7)
Close fi re grate. Push in fi re grate slider.
Add two logs weighing approx.
1,7 kg in total. Place logs with
one end to the front of fi re box.
Only add a single layer of fuel.
Open fi re box door.
Close fi re box door.
Tab. 2
Heating with Brown Coal Briquettes
Procedure Position of
Control Elements
Open primary air completely.
Adjust secondary air.
Pull primary air slider (I)
all the way out (fi g. 8)
Set secondary air slider (II)
to position 2. (fi g. 8)
Open fi re grate. Pull out fi re grate slider.
Tab. 3
g. 7
g. 8
(I)
(II)
(I)
(II)