Note
General sensor unit care
Time & Date settings on the sensor unit (which are included with files and batch labels) are updated automatically through a
FireWire/Phocus connection. These settings are retained for about two consecutive weeks by a small rechargeable cell that is auto-
matically recharged by the main battery or FireWire with regular use. If problems occur, charge the cell by leaving the sensor unit
turned ON for around 12 hours.
Do not touch the exposed CCD/filter with your fingers.
Always replace the protective CCD/filter cover when the sensor unit is not mounted on a camera.
Never attempt to remove the glass filter from the front of the CCD–you will probably ruin the CCD if you do so. If dust manages to
get between the IR filter and CCD, it can only be removed at the Hasselblad factory. Contact your Hasselblad dealer for assistance.
Store the sensor unit away from moisture and excessive heat.
When cleaning the filter, take at least as much care as you would with any optic. See under Appendix for cleaning instructions.
Approval/(OK)button F
This button steps through the three approval levels,
thereby assigning an approval status to the image
currentlydisplayed(orselected)inthepreviewscreen.
(partoftheInstantApprovalArchitecturesystem).Alsoactsasacon-
rmationbutton(OKbutton)forvariousmenuoperations,suchasde-
letingimages;indicatedbyalabelbesidethebuttononthepreview
screen.
Busy-light G
Flashes to indicate that the sensor unit is performing an operation
(such as saving a new capture). Although a new capture cannot be
madewhilethelightisashing,focusing,apertureandshutterspeed
settingscanallbechanged.
Redsigniesaproblem(anexplanatorymessagewillbedisplayed).
Safety catch H
Usedwhenremovingthesensorunit.
CCDandIRlter I
The sensor is positioned behind a permanently mounted IR lter.
Alwaysbeverycarefulnottotouchorscratchthesurfaceofthelter
whenitisexposed.
Replacetheprotectivecoverwheneverthesensor
unitisnotmountedonacamera.
Databus connectors J
Fordigitalcommunicationwithcamerabody.
Flash-card slot K
Flash-card removal button L
Flash-card slot cover M
(H4D-31 / 40 / 50 only)
Flashsyncinput N
Flashsyncconnector(protectedbehindarubbercover)forwhenthe
sensorunitisusedwithaview/largeformatcamera.
Flashsyncoutput O
Flashsyncconnector(protectedbehindarubbercover)forwhenthe
sensorunitisusedwithaview/largeformatcamera.
FireWire connector P
FireWire800portforcomputerconnection.
(H4D-60 only)
Flash sync & power connectors Q
Connectors(protectedbehindarubber cover) usedwhenthesensor
unitismountedonaview/largeformatcamera.
FireWire connector R
FireWire800portforcomputerconnection.