STC-200 Thermostat
Quick Start Guide
(Version 21.08.02GEN)
STC-200+ thermostat with just one relay to control the
power supply status of the wired heater or cooler or
output alarm.
1. Wiring Diagram
2. Set the Aimed Temp Range
The aimed temperature range was defined from “SP” to
“SP + F0”; hence you need to set both the “SP” and the
F0” value.
Question and Answer IconNeed help?

Do you have a question about the Haswill STC-200 and is the answer not in the manual?

Summary

Wiring Diagram

Set the Aimed Temp Range

Function Menu

Set the SP value

Press the Set key to view SP value, then use arrow keys to change it.

Set the Hysteresis Value

Hold Set + Up keys, then use Set key to change F0 (Hysteresis) value.

Overview

The STC-200+ is a thermostat designed for controlling the power supply status of a wired heater or cooler, or for triggering an output alarm. This device is characterized by its simplicity, featuring just one relay for control.

Technical Specifications:

  • Model: STC-200+
  • Power Supply: 10A/220VAC
  • Version: 21.08.02GEN
  • Control Output: Single relay, suitable for heater, cooler, or alarm.
  • Sensor: Included, with connections for NC (Normally Closed) and Sensor.
  • Load Capacity: 10A at 220VAC.

Function Description:

The primary function of the STC-200+ is to maintain a desired temperature range by activating or deactivating a connected heating or cooling device. It operates based on a user-defined "SP" (Set Point) value and a "Hysteresis" (Temperature Difference) value. The device also includes features for protection delay and calibration.

Usage Features:

  1. Wiring Diagram: The device features a clear wiring diagram for easy installation.

    • Terminals 1 and 2 are for the 10A/220VAC power input.
    • Terminals 3 and 4 are for the load (heater, cooler, or alarm).
    • Terminals 5, 6, and 7 are for the sensor connections, with 5 being NC (Normally Closed) and 6-7 being for the sensor itself.
  2. Setting the Aimed Temperature Range: The desired temperature range is defined by two parameters: "SP" (Set Point) and "FO" (Hysteresis/Difference).

    • Setting the "SP" value:
      • Press the "Set" key to view the existing SP value.
      • Use the "Up" or "Down" keys to adjust the SP value. The adjustable range is limited by F2 (Lower Limit for SP Setting) and F3 (Upper Limit for SP Setting).
      • The device will automatically return to normal status from the setting interface after 30 seconds of inactivity.
    • Setting the "Hysteresis" Value (FO):
      • Hold the "Set" and "Up" keys simultaneously for 4 seconds. The display will show "FO".
      • Press the "Set" key again to view the current Hysteresis value.
      • Use the direction keys (Up/Down) to change the value.
      • Press the "Set" key to save the new data and return to the menu list.
  3. Function Menu (Code and Function): The STC-200+ offers several configurable functions accessible through a menu:

    • FO (Temperature Hysteresis / Difference): Defines the temperature difference between the set point and the activation/deactivation point.
    • F1 (Protection Delay Time for the Compressor): Sets a delay before the compressor (or connected device) starts, protecting it from rapid cycling.
    • F2 (Lower Limit for SP Setting): Establishes the minimum allowable value for the Set Point.
    • F3 (Upper Limit for SP Setting): Establishes the maximum allowable value for the Set Point.
    • F4 (Refrigeration or Heating or Alarm Mode): Configures the device for cooling, heating, or alarm operation.
    • F5 (Calibration = Real - Measured): Allows for sensor calibration to ensure accurate temperature readings.
  4. Saving Settings and Exiting:

    • To save data and return to the normal monitor status, hold the "Set" key for 3 seconds.
    • To quit from setting or leave it alone, hold the "Set" key for 3 seconds. The device will automatically revert to normal status within 30 seconds if no operation is performed.

Maintenance Features:

  • Calibration (F5): The calibration function allows users to adjust the sensor reading to match a known accurate temperature, ensuring the device provides precise control over time. This helps maintain the accuracy of the temperature readings and, consequently, the effectiveness of the control.

Important Notes:

  • This document serves as a quick start guide, highlighting key points. For a comprehensive understanding and detailed instructions, users are advised to refer to the full-content version user manual, which can be accessed via the provided QR code or URL.
  • The device is designed for simplicity, focusing on essential temperature control functions with a single relay output.
  • Proper wiring according to the provided diagram is crucial for safe and effective operation.

Haswill STC-200 Specifications