Haswill STC-9200 - Defrosting Cycle;Interval Time (F6); Defrosting Lasting;Running Time (F7); Defrosting Stop Temperature (F8)

Haswill STC-9200
9 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 / 9
Time Condition 1: the real-time passes the preset
interval time F6 (IDF), a regular parameter for almost all
defrosting thermostats.
Time Condition 2: If the "defrosting method" you take is
the hot gas from the compressor reverse rotary when F10
= 1 (TDF = HTG), it will count the compressor's last stops
moment plus F5 (ac), which is a protective value to avoid
the compressor frequently startup and stops.
The operates method is just like page 1 shows;
6) F6 (IDF): Defrosting Cycle / Interval Time
7) F7 (ADF): Defrosting Lasting/Running Time
8) F8 (DTE): Defrosting Stop Temperature