Activate mechanical oil pressure monitor
(optional extra), chap. 4.1.4.
Run the engine briefly to check the fuel filter
and lines for leaks.
5.4.2. Dry-type air cleaner maintenance
It is best to clean the filter cartridge only when
the maintenance indicator displays the appropri-
ate signal.
Apart from this, the cartridge should be renewed
after 500 hours of operation.
50
In case of the enclosed design, please remove
the cover of the enclosure in the order 1...2.
The decompression lever is also taken off
when the cover is removed.
51
Slacken off wing bolt „1“ and remove it with
cover „2“.
52
Carefully pull out filter cartridge „1“.
On the version with air cleaner maintenance
indicator, check that valve plate „4“ is clean
and in good condition.
Clean filter housing and cover.
Make sure that dirt or other foreign matter
cannot enter the engine air intake port.