Type of fault Possible causes Remedy Chapter
Poly v belt torn. Renew the poly v
belt.
8.2.8 Re-
placing the
poly v belts,
page 69
Mechanical faults. Contact Hatz serv-
ice.
Engine switches off
by the automatic
electrical switch-off.
Stop signal of mon-
itoring elements
for:
Oil pressure too
low.
Dirty air filter
unit.
Fuel pressure
too low.
Coolant level too
low.
Excess coolant
temperature.
Excess charge
air temperature.
Faulty three
phase alternator.
Check the oil lev-
el.
Check the de-
gree of dirt con-
tamination of the
air filter, and
clean or renew it
if necessary.
Check the fuel
flow, if necessary
change the fuel
prefilter and fine
filter.
Top up coolant.
Check radiator
fins and clean if
needed.
Contact Hatz
service.
7.6 Check-
ing the oil
level and
adding oil if
necessary,
page 47
8.2.14 Serv-
icing the air
filter (option-
al), page 80
8.2.12
Changing
the fuel pre-
filter,
page 74
8.2.13
Changing
the fuel fine
filter,
page 77
8.2.4
Checking
the cooling
system,
page 57
8.2.6 Clean-
ing the radi-
ator fins,
page 64