Type of fault Possible causes Remedy Chapter
Stop signal from
monitoring ele-
ments that are as-
sociated with the
automatic switch-
off (optional):
No oil pressure.
Dirty air filter
unit.
Fuel pressure
too low.
Coolant level too
low.
Excess coolant
temperature.
Excess charge
air temperature.
Faulty three
phase alternator.
Check the oil lev-
el.
Check the de-
gree of dirt con-
tamination of the
air filter, and
clean or renew it
if necessary.
Check the fuel
flow, if necessary
change the fuel
prefilter and fine
filter.
Top up coolant.
Check radiator
fins and clean if
needed.
Contact Hatz
service.
7.6 Check-
ing the oil
level and
adding oil if
necessary,
page 47
8.2.14 Serv-
icing the air
filter (option-
al), page 80
8.2.12
Changing
the fuel pre-
filter,
page 74
8.2.13
Changing
the fuel fine
filter,
page 77
8.2.4
Checking
the cooling
system,
page 57
8.2.6 Clean-
ing the radi-
ator fins,
page 64
Engine switches off
spontaneously dur-
ing operation.
The tank ran out of
fuel during opera-
tion
Fill with fuel. 7.7 Refuel-
ing, page 49
Fuel prefilter or fine
filter is clogged
Change the fuel fil-
ter.
8.2.12
Changing
the fuel pre-
filter,
page 74
8.2.13
Changing
the fuel fine
filter,
page 77
4H50TIC Faults