4.2.2 - "Platform" control panel
Photo 2: Platform control panel
DURING HIGH PRESSURE
WASHING, DO NOT DIRECT THE
JET AT THE ELECTRIC BOXES AND
CABINETS
4.2.3 - Checks before use
• Make sure that the machine is on a flat, stable floor that can take the
weight of the machine
• Visually inspect the w hole machine for pain t ch ips, le aking ba ttery
acid, etc.
• Check that there are no loose bolts, nuts, connections or hoses, no oil
leaks, no broken or disconnected electric wires.
• Check the mast, chassis, stabiliser bars and platform: no visible da-
mage, no indications of wear or deformation.
• Check that there are no leaks, traces of wear or impact, scratches,
rust or foreign matter on the jack rods.
• Hydraulic unit and pump: no leaks, tight components.
• Check the level of hydraulic oil: top up if necessary.
• Check that the battery terminals are clean and tight: slack or corroded
terminals may result in a loss of power.
• Check battery charge: recharge if necessary.
These machines are not insulated
and must not be used near electric
lines.
• Check that the platform control panel power cable is in good condi-
tion.
• Check correct operation of the emergency stops.
• Check that the labels are clean and legible.
• Check that the wheels work properly.
• Visually check the underside of the chassis.
10 - Emergency stop button
11 - Up/down switch
12 - Start button
307P220200 c