23
6. APPENDIX (continued)
REMARKS:
AT : AIR TEMPERATURE SENSOR LP : LOW PRESSURE SWITCH
COMP : COMPRESSOR OT : OUTLET WATER TEMPERATURE SENSOR
CT : EVAPORATOR TEMPERATURE SENSOR SUT : SUCTION TEMPERATURE SENSOR
EEV : ELECTRONIC EXPANSION VALVE 4V : 4 WAYS VALVE
FM : FAN MOTOR K2 : DRY CONTACT 16 A MAX
FS : WATER FLOW SWITCH ET : DISCHARGE TEMPERATURE SENSOR
HP : HIGH PRESSURE SWITCH PS : PRESSURE SENSOR
IT : WATER INLET TEMPERATURE SENSOR
ENPI6M
U W
CN21
RES1
CN29
OVT
CN30
HP
CN31
LP
CN13
HEAT
CN18
EMV
CN66
RY
CN11
FOUR
CN96
OT(RED)
P14L
P13L
CN7
OAT
CN8
OPT
CN22
RES2
CN9
OHT
CN12
PH
FS LP
A B
RS485
CN15
LEV1
CN24
LEV2
AT(WHT)
4V
K2
ACL
ACN
L
N
GND
A
B
reactor
EEV
5
GND
COMP
U
V
W
U
W
V
RED
BLK WHT
FM
V
FILTER
L
N1
L1
N
A
B
RED
WHT
YEL
BLK
ACL1
ACN1
IT(BLU)
SUT(GRN)
CT(YEL)
Magetic ring
HP
HP
EP
EP
HP
EP
GRN
t
50K
ET(GRY)
DCFAN
CN97
SPS
CN2 CN1
2AC32I12WO1
CN99
PL
RED
WHT
BLK
PSSUT
P03
4
BLU
t
5K
t
5K
t
5K
t
5K
t
5K
BRN
L N
1
2
1
2
220-240V~/50Hz
L
N
RED
BLU
TO POWER
SUPPLY
Y/G
K2
Dry Contact
YEL 485B-
RED 12V
WHT 485A+
Controller
BLK GND
WiFi
BLK GND
YEL 485B-
WHT 485A+
RED 12V
Power supply
220-240V/50Hz

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hayward Energyline Pro Inverter Series and is the answer not in the manual?

Hayward Energyline Pro Inverter Series Specifications

General IconGeneral
BrandHayward
ModelEnergyline Pro Inverter Series
CategoryHeat Pump
LanguageEnglish

Related product manuals