Hayward Easy Temp ECP 15 - User Manual

Hayward Easy Temp ECP 15
398 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
POMPE A CHALEUR POUR PISCINE
SWIMMING POOL HEAT PUMP UNIT
UNIDAD DE BOMBA DE CALOR PARA PISCINAS
BOMBA DE AQUECIMENTO PARA PISCINAS
HEIZPUMPENANLAGE FÜR EIN SCHWIMMBECKEN
ZWEMBAD WARMTEPOMP
UNITÀ DI RISCALDAMENTO A POMPA DI CALORE PER PISCINE
VARMEPUMPE TIL SVØMMEBASSENG
LÄMPÖPUMPPU UIMA-ALTAALLE
VÄRMEPUMP FÖR BASSÄNG
ɌȿɉɅɈȼɈɃɇȺɋɈɋȾɅəɉɅȺȼȺɌȿɅɖɇɈȽɈȻȺɋɋȿɃɇȺ
Manuel d’instructions et d’installation
Installation & Instruction Manual
Manual de Instalación e Instrucciones
Manual de instalação e de instruções
Einbau- & Anleitungshandbuch
Installatie- en bedieningshandleiding
Manuale d’Uso e di Installazione
Installerings- og brukerveiledning
Asennus- ja ohjekirja
Bruksanvisning och installationsmanual
Ɋɭɤɨɜɨɞɫɬɜɨɩɨɦɨɧɬɚɠɭɢɷɤɫɩɥɭɚɬɚɰɢɢ
ISECP - Rev B

Table of Contents

Questions and Answers

  • A
    Adam CarterAug 17, 2025
    What to do if my Hayward Heat Pump shows high pressure protection?
    • K
      kristin97Aug 17, 2025
      High pressure protection in your Hayward Heat Pump can occur if the refrigerating circuit pressure is too high, the water flow is too low, the coil is obstructed, or the air flow is too weak. You should check the high pressure switch and the refrigerating circuit pressure. Also, check the water or air flow, ensure the flow controller is working properly, verify that the water inlet/outlet valves are opening, and review the by-pass settings.
  • J
    Jessica JonesAug 20, 2025
    Why does my Hayward Easy Temp ECP 15 Heat Pump have low pressure protection?
    • M
      Molly BellAug 20, 2025
      Low pressure protection in your Hayward Heat Pump can be triggered by refrigerating circuit pressure being too low, air flow being too weak, or the coil being obstructed. Check the low pressure switch and the refrigerating circuit pressure to see if there is a leak. Clean the coil surface, check the fan rotation speed, and ensure free circulation of air through the coil.
  • F
    fbaileyAug 22, 2025
    What causes a large temperature difference between inlet and outlet water in my Hayward Heat Pump?
    • R
      Ricky TorresAug 22, 2025
      A temperature difference that is too great between the outlet and inlet water in your Hayward Heat Pump can be caused by insufficient water flow volume, or water pressure difference being too low or too high. Check the water flow or for a system obstruction.
  • P
    Patricia MorrisAug 26, 2025
    What to do if Hayward Easy Temp ECP 15 Heat Pump shows flow sensor fault?
    • S
      Samantha LeAug 26, 2025
      If your Hayward Heat Pump displays a flow sensor fault, it might be due to insufficient water flow, or the sensor being short-circuited or faulty. Check the water flow, the filtration pump, and the flow sensor for any faults.
  • P
    pricechristopherAug 28, 2025
    Why does my Hayward Heat Pump show antifreeze protection in cold mode?
    • A
      Alexandra TranAug 28, 2025
      Antifreeze protection Cold mode in your Hayward Heat Pump is often due to the water outlet quantity being too low. Check the water flow rate or the outlet water temperature sensor.
  • S
    Steven WoodwardAug 31, 2025
    What does Level 1 antifreeze protection mean on my Hayward Easy Temp ECP 15 Heat Pump?
    • L
      leedawsonAug 31, 2025
      If your Hayward Heat Pump shows a Level 1 antifreeze protection, it is because the air and inlet water temperature is too low. Turn off the heat pump and drain the capacitor because there is a freezing risk.
  • S
    Sydney PattersonSep 2, 2025
    What should I do if my Hayward Easy Temp ECP 15 displays Level 2 antifreeze protection?
    • J
      Joshua NelsonSep 3, 2025
      If your Hayward Heat Pump shows a Level 2 antifreeze protection, it is because the air and inlet water temperature is even lower. Turn off the heat pump and drain the capacitor because there is a freezing risk.
  • T
    Tiffany PierceSep 5, 2025
    How to fix communication problem on Hayward Easy Temp ECP 15 Heat Pump?
    • A
      Angela KennedySep 5, 2025
      A communication problem with your Hayward Heat Pump is caused by a LED controller or PCB connection fault. Check the wiring.
  • E
    Emily JeffersonSep 8, 2025
    How to troubleshoot water inlet sensor fault on Hayward Easy Temp ECP 15 Heat Pump?
    • S
      Stephen LewisSep 8, 2025
      To address a water inlet sensor fault in your Hayward Heat Pump, check or replace the sensor.
  • D
    Devon RobinsonSep 12, 2025
    How to troubleshoot water outlet sensor fault on Hayward Heat Pump?
    • M
      Mark WilliamsSep 12, 2025
      To address a water outlet sensor fault in your Hayward Heat Pump, check or replace the sensor.

Summary

Technical Specifications

Swimming Pool Heat Pump Technical Data

Detailed specifications including capacity, power, current, connections, and dimensions.

Operating Range

Specifies temperature and humidity ranges for safe and efficient heat pump operation.

Installation and Connection

Electrical Connection Standards and Requirements

Details electrical standards, power supply, and connection box information.

Initial Start-Up Procedure and Notes

Step-by-step guide for powering up, verification, and operational notes for initial startup.

Water Flow Setting

Instructions on adjusting the bypass valve to achieve the correct water temperature difference.

User Interface

Setting and Viewing Set Point

How to adjust and view the desired water temperature.

Maintenance and Winterisation

Appendices

Wiring Diagrams

Electrical schematics for different heat pump models.

Troubleshooting Guide

Lists common faults, error codes, descriptions, and solutions for the heat pump.

Warranty Information

Details the warranty conditions, duration, and claim procedures for Hayward products.

Hayward Easy Temp ECP 15 Specifications

General IconGeneral
BrandHayward
ModelEasy Temp ECP 15
CategoryHeat Pump
LanguageEnglish