POMPE A CHALEUR POUR PISCINE
SWIMMING POOL HEAT PUMP UNIT
UNIDAD DE BOMBA DE CALOR PARA PISCINAS
BOMBA DE AQUECIMENTO PARA PISCINAS
HEIZPUMPENANLAGE FÜR EIN SCHWIMMBECKEN
ZWEMBAD WARMTEPOMP
UNITÀ DI RISCALDAMENTO A POMPA DI CALORE PER PISCINE
VARMEPUMPE TIL SVØMMEBASSENG
ТЕПЛОВОЙ НАСОС ДЛЯ ПЛАВАТЕЛЬНОГО БАССЕЙНА
Manuel d’instructions et d’installation
Installation & Instruction Manual
Manual de Instalación e Instrucciones
Manual de instalação e de instruções
Einbau- & Anleitungshandbuch
Installatie- en bedieningshandleiding
Manuale d’Uso e di Installazione
Installerings- og brukerveiledning
Руководство по монтажу и эксплуатации
ENERGYLINE PRO
INVERTER
ISENPINVR32

Table of Contents

Questions and Answers

  • C
    Christine TaylorSep 4, 2025
    What should I do if my Hayward Heat Pump displays level 2 antifreeze protection?
    • J
      John HaynesSep 4, 2025
      If your Hayward Heat Pump is experiencing Level 2 antifreeze protection, where the water temperature is below 2°C and the air temperature is below 0°C, stop the heat pump operation. Empty the condenser to avoid freezing. By default, the heat pump starts the filtration pump and the heat pump to prevent icing over.
  • J
    Juan TaylorSep 18, 2025
    How to resolve communication problem in Hayward ENPI6M?
    • N
      Nicholas YoungSep 18, 2025
      To resolve a communication problem with your Hayward Heat Pump, check the connectors, referring to the wiring diagram for guidance.
  • K
    Kevin ArmstrongSep 16, 2025
    What does a compressor discharge sensor fault mean on my Hayward ENPI6M Heat Pump?
    • G
      graystevenSep 16, 2025
      To address a compressor discharge sensor fault in your Hayward Heat Pump, verify the CN9/OHT connectors on the board and the extension connector, or replace the sensor.
  • R
    Reginald BarrySep 14, 2025
    How to troubleshoot a compressor aspiration sensor defect in Hayward ENPI6M?
    • J
      Judy BennettSep 14, 2025
      To address a compressor aspiration sensor defect in your Hayward Heat Pump, verify the CN7/OAT connectors on the board and the extension connector, or replace the sensor.
  • R
    Rachel VazquezSep 12, 2025
    What should I do if my Hayward Heat Pump shows a de-icing sensor fault?
    • M
      Matthew SimpsonSep 12, 2025
      To address a de-icing sensor fault in your Hayward Heat Pump, verify the CN8/OPT connectors on the board and the extension connector, or replace the sensor.
  • J
    Jordan BoydSep 12, 2025
    How can I fix the outside temperature sensor fault on my Hayward Heat Pump?
    • D
      Dawn GaySep 12, 2025
      To address an outside temperature sensor fault in your Hayward Heat Pump, verify the CN12/PH connectors on the board and the extension connector, or replace the sensor.
  • S
    Sara DavisSep 9, 2025
    How do I resolve a water outlet sensor fault on my Hayward ENPI6M Heat Pump?
    • C
      Cynthia RobinsonSep 9, 2025
      To address a water outlet sensor fault in your Hayward Heat Pump, verify the N22/RES2 connectors on the board and the extension connector, or replace the sensor.
  • M
    Mrs. Jessica ThorntonSep 7, 2025
    What causes a pressure sensor fault in my Hayward ENPI6M Heat Pump?
    • C
      Catherine MendezSep 7, 2025
      If your Hayward Heat Pump is experiencing a pressure sensor fault because the sensor is open or short-circuiting, check the connections using the electrical diagram.
  • N
    Nathan NicholsSep 5, 2025
    Why does my Hayward ENPI6M stop when the exterior temperature is too low?
    • D
      Donna AdamsSep 6, 2025
      If your Hayward Heat Pump stops due to the exterior temperature being too low, this means the operating limit has been reached. Stop the heat pump.
  • E
    Elizabeth BrowningAug 20, 2025
    What to do if my Hayward Heat Pump shows high pressure protection?
    • T
      triveraAug 21, 2025
      To address high pressure protection issues with your Hayward Heat Pump, several factors should be verified. Begin by checking the water flow and ensuring the water flow detector is functioning correctly. Inspect the valve opening and by-pass to confirm they are properly adjusted. Make sure the evaporator is not clogged. Verify that the water temperature isn't too high. If the issue occurred after maintenance, empty and evacuate the cooling circuit to eliminate any incondensable problems. If the fluid load is too high, remove fluid into a liquid bottle.

Summary

Safety and Handling Precautions

General Safety Instructions

Critical safety advice for installation, operation, and maintenance of the heat pump.

Refrigerant Safety and Handling

Information on R32 refrigerant, storage, and safe handling practices.

Technical Specifications Overview

Detailed Unit Technical Data

Comprehensive technical specifications including electrical, performance, and physical data.

Operating Range Specifications

Defines the permissible temperature and humidity ranges for unit operation.

Installation and Connection Procedures

Hydraulic Connections and Bypass Valve

Steps for connecting water pipes and installing a bypass valve for maintenance.

Electrical Connection Standards

Guidance on local electrical standards and proper wiring practices for the unit.

User Interface and Control Panel

Maintenance and Winterisation Guide

Appendix: Technical Information

Troubleshooting Common Issues

Guide to diagnosing and resolving error codes and operational problems.

Hayward ENPI6M Specifications

General IconGeneral
ModelENPI6M
CategoryHeat Pump
Compressor TypeScroll
Voltage208/230V
PhaseSingle
RefrigerantR410A