EasyManua.ls Logo

Hayward H250FD - Specific Hazard Warnings

Hayward H250FD
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
4
NOTES TO THE ELECTRICIAN:
Useasolidcopperconductor,size8orlarger.Runacontinuouswirefromexternalbondinglugtorein-
forcingrodormesh.ConnectaNo.8AWGsolidcopperbondingwiretothegroundinglugprovidedonthe
heaterandtoallmetalpartsofswimmingpoolorspa,andtoallelectricalequipment,metalpiping(except
gaspiping),andconduitwithin5ft.(1.5m)ofinsidewallsofswimmingpoolorspa.
IMPORTANT-ReferenceNECcodesforallwiringstandardsincluding,butnotlimitedto,grounding,
bondingandothergeneralwiringprocedures.
WARNING – Suction Entrapment Hazard.
Suctioninsuctionoutletsand/orsuctionoutletcoverswhicharedamaged,broken,
cracked,missing,orunsecuredcancausesevereinjuryand/ordeathduetothefol-
lowingentrapmenthazards:
Hair Entrapment-Haircanbecomeentangledinsuctionoutlets.
Limb Entrapment-Alimbinsertedintoanopeningofasuctionoutletorsuctionoutlet
coverthatisdamaged,broken,cracked,missing,ornotsecurelyattachedcanresultina
mechanicalbindorswellingofthelimb.
Body Suction Entrapment-Adifferentialpressureappliedtoalargeportionofthebodyorlimbscan
resultinanentrapment.
Evisceration/ Disembowelment-Avacuumapplieddirectlytotheintestinesthroughanunprotected
suctionoutletsumporsuctionoutletcoverwhichisdamaged,broken,cracked,missing,orunsecured
canresultinevisceration(disembowelment).
Mechanical Entrapment-Thereispotentialforjewelry,swimsuit,hairdecorations,nger,toeorknuck-
letobecaughtinanopeningofasuctionoutletorsuctionoutletcoverresultinginmechanicalentrap-
ment.
WARNING-Toreducetheriskofentrapmenthazards:
• Whensuctionoutletsarelessthana18”x23”equivalent,aminimumoftwofunction-
ingsuctionoutletsperpumpmustbeinstalled.Suctionoutletsinthesameplane(i.e.
oororwall),mustbeinstalledaminimumofthreefeet(3’)[1meter]apart,asmea-
suredfromnearpointtonearpoint.
• Dualsuctionoutletsshallbeplacedinsuchlocationsanddistancestoavoid“dual
blockage”byauser.
• Dualsuctionttingsshallnotbelocatedonseatingareasoronthebackrestforsuch
seatingareas.
• Themaximumsystemowrateshallnotexceedtheowratingofanylisted(percurrentrevisionof
ASME/ANSIA112.19.8)suctionoutletcoverinstalled.
• NeverusethePoolorSpaifanysuctionoutletcomponentisdamaged,broken,cracked,missing,or
notsecurelyattached.
• Replacedamaged,broken,cracked,missing,ornotsecurelyattachedsuctionoutletcomponentsim-
mediately.
• InstalltwoormoresuctionoutletsperpumpinaccordancewithlatestAPSP(formallyNSPI)Stan-
dardsandCPSCguidelines.FollowallapplicableNational,State,andLocalcodes.