Hayward/Summit Heat Pump
Troubleshooting Guide
© 2012 Hayward Industries
Question and Answer IconNeed help?

Do you have a question about the Hayward HeatPro HP20654T and is the answer not in the manual?

Hayward HeatPro HP20654T Specifications

General IconGeneral
BrandHayward
ModelHeatPro HP20654T
CategoryHeat Pump
LanguageEnglish

Summary

Safety and Warnings

General Safety Precautions

Emphasizes EPA regulations for refrigerant handling and servicing by trained personnel due to electric shock risk.

High Voltage Danger

Warns of high voltage and extreme caution, advising against attempting service without qualification.

Common Error Codes: LP

LP Error Code Explanation

LP indicates the low pressure switch is open, usually due to refrigerant pressure dropping below 80PSI.

Troubleshooting LP Errors

Common causes include refrigerant leaks, bad fan motor/capacitor, or a faulty LP switch.

Common Error Codes: HI/HP

HI/HP Error Code Explanation

HI or HP indicates the high pressure switch is open, often due to restricted water flow or TXV failure.

Troubleshooting HI/HP Errors

Primary cause is restricted water flow; also covers TXV failure and refrigerant overcharge.

Common Error Codes: PO/OP

PO/OP Error Code Explanation

PO or OP indicates an open water temperature sensor.

Troubleshooting PO/OP Errors

Check sensor wiring and resistance; replace sensor or control board if necessary.

Common Error Codes: Pc/SH

Pc/SH Error Code Explanation

Pc or SH indicates a shorted water temperature sensor.

Troubleshooting Pc/SH Errors

Check sensor wiring and resistance; replace sensor or control board if necessary.

Common Error Codes: dPO/cOP

dPO/cOP Error Code Explanation

dPO or cOP indicates an open defrost temperature sensor.

Troubleshooting dPO/cOP Errors

Check sensor wiring and resistance; replace sensor or control board.

Common Error Codes: dPc/cSH

dPc/cSH Error Code Explanation

Pc or SH indicates a shorted defrost temperature sensor.

Troubleshooting dPc/cSH Errors

Check sensor wiring and resistance; replace sensor or control board.

Temperature/Resistance Charts

Common Error Codes: Flo/PS

Flo/PS Error Code Explanation

Flo or PS indicates an open water pressure switch, usually related to water flow.

Troubleshooting Flo/PS Errors

Check filter, pump, and bypass; test pressure switch continuity and adjust/replace if needed.

Common Error Codes: Blank Display

Common Error Codes: FS/deF

Hot Gas Bypass (HGBP)

HeatPro Wiring Diagram

Summit/HeatMaster/EnergyTherm/EasyTemp Wiring Diagram

Heat Pump Specifications

Flow Chart: PS/FLo

Flow Chart: HI/HP

Flow Chart: OP/PO – SH/Pc

Flow Chart: COP/dPO – cSH/dPc

Flow Chart: LP

Alternative Leak Detection Methods

Related product manuals