Hayward HeatPro HP20854BT Specifications

General IconGeneral
ModelHP20854BT
CategoryHeat Pump
Voltage208-230V
PhaseSingle
RefrigerantR410A
COP5.0
Hertz60 Hz
Warranty2 years

Summary

Important Safety Information

General Safety Precautions

Essential safety guidelines for operating and servicing heat pumps, including EPA regulations.

Normal Heat Pump Operation Parameters

Refrigerant Operating Pressures

Details normal low and high side refrigerant pressures for heat pumps.

Heat Pump Water Management and Leak Detection

Troubleshooting LP Error Code

LP Error Code Definition

Explains the meaning of the LP error display, indicating a low-pressure switch opening.

LP Error Troubleshooting Steps

Guides on diagnosing and resolving LP error codes, including refrigerant loss and switch issues.

Troubleshooting HI/HP Error Codes

HI/HP Error Code Definition

Explains the meaning of the HI/HP error display, indicating a high-pressure switch opening.

HI/HP Error Troubleshooting Steps

Guides on diagnosing and resolving HI/HP error codes, including restricted water flow and TXV failure.

Troubleshooting PO/OP and Pc/SH Errors

PO/OP Error Diagnosis and Resolution

Covers PO/OP errors related to open water temperature sensors, their causes, and fixes.

Pc/SH Error Diagnosis and Resolution

Covers Pc/SH errors related to shorted water temperature sensors, their causes, and fixes.

Troubleshooting dPO/cOP and dPc/cSH Errors

dPO/cOP Error Diagnosis and Resolution

Covers dPO/cOP errors related to open defrost sensors, their causes, and fixes.

dPc/cSH Error Diagnosis and Resolution

Covers dPc/cSH errors related to shorted defrost sensors, their causes, and fixes.

Sensor Temperature-Resistance Charts

Summit Sensor Resistance Data

Resistance values for Summit heat pump sensors at various temperatures.

HeatPro Sensor Resistance Data

Resistance values for HeatPro heat pump sensors at various temperatures.

Troubleshooting Flo/PS Error

Flo/PS Error Definition

Explains the meaning of the Flo/PS error display, indicating water flow issues.

Flo/PS Error Troubleshooting Steps

Guides on diagnosing and resolving Flo/PS error codes, focusing on water flow.

Troubleshooting Blank Display Error

Troubleshooting FS/deF Error and Defrost

Hot Gas Bypass (HGBP) Troubleshooting

HeatPro Wiring Diagram

Summit Series Wiring Diagram

Summit Series Setup Menu and Functions

Heat Pump Specifications Overview

Troubleshooting Flow Chart: PS/FLo

Troubleshooting Flow Chart: HI/HP

Troubleshooting Flow Charts: OP/PO & SH/Pc

Troubleshooting Flow Chart: LP

Advanced Leak Detection Methods