Installation
Installation Manual 25
Forming The Piping
Form the piping by wrapping the connecting
portion of the indoor unit with insulation material
and secure it with two kinds of vinyl tapes.
If you want to connect an additional drain hose, the
end of the drain outlet should be routed above the
ground. Secure the drain hose appropriately.
In cases where the outdoor unit is installed
below the indoor unit perform the following.
Tape the piping, drain hose and connecting cable
from down to up.
Secure the taped piping along the exterior wall using
saddle or equivalent.
Taping
Drain
hose
Pipings
Connecting
cable
Trap is required to prevent water
from entering into electrical parts.
Seal small openings
around pipings with a
gum type sealer.
In cases where the Outdoor unit is installed
above the Indoor unit perform the following.
Tape the piping and connecting cable from down to
up.
Secure the taped piping along the exterior wall.Form
a trap to prevent water entering the room.
Fix the piping onto the wall by saddle or equivalent.
Seal a small opening
around the pipings
with gum type sealer.
Trap
Trap