Heat Controller MSS-024B/A - Page 56

Heat Controller MSS-024B/A
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8.
The
phenomena
in
case
of
connecting
error
INDOOR
UNIT
Connector
Type
Condition
Phenomena
CN-DC/DC
Open
and
connecting
error
"
The
same
as
the
phenomenon
of
Outdoor
Unit.
p
Blue
Q
Black
(D
Brown
©
Red
CN-MOTOR
Open
-The
indoor
fan
does
not
operate.
"
The
operation
indicator
of
Indoor
unit
blinks
8
times.
Open
"
The
up/down
vane
does
not
operate.
CN-UP/DOWN
Short
between
terminals
"
The
up/down
vane does
not
smoothly
operate.
CN-DISP
Open
"
It
does
not
operate
with
a
remote
controller.
"
The
operation
indicator
blinks
once.
On
for 0.5
second
Open
Ott
ior
3
seconds
"
The
compressor
and
the
outdoor
fan
stop.
"
The
indoor
fan
speed
is
low.
CN-TH
"
The
operation
indicator
blinks
once
Short
between
terminals
(on
for
0.5
second,
off
for
3
seconds).
((I
and
®)
of
ROOM-TH.
"
The
compressor
operates
continuously
regardless
of
the
setting
temperature
and
the
variation
of
room
temperature.
Short
between
terminals
"
The
operation
indicator
blinks
once
(T
and
®)
of
PIPE-TH.
(on for
0.5
second,
off
for
3
seconds)
"
Continuous
operation
-56-