Installation and Servicing
High Effi ciency Condensing Combination Boilers
www.heatline.co.uk
Models
24
G.C. No. 47-157-21
28 G.C. No. 47-157-22
Monza
Service Call 0844 736 9042, Technical Help (Chargeable) Call 0906 802 0253
bar
1
2
3
4
0
mode
reset

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Heat Line Monza 28 and is the answer not in the manual?

Heat Line Monza 28 Specifications

General IconGeneral
Mounting typeWall-mounted
Number of circuits2
Closed combustion chamberYes
Maximum thermal power28 kW
Maximum heat output28 kW
Minimum heat output5.6 kW
Power consumption110 W
Power supply voltage230 V
Width400 mm
Height700 mm
TypeGas
Output (DHW)28 kW
Max working pressure3 bar
Electrical supply230 V / 50 Hz
Expansion tank volume8 liters
Gas typeNatural gas
Dimensions (HxWxD)700x400x299 mm

Summary

Introduction

Instructions Guidance

Details on product documentation, associated documents, symbols, and guarantee registration.

Appliance Description

Overview of the boiler's components, safety features, and functions.

Appliance Description

Safety Instructions and Regulations

Safety Instructions

Essential safety guidelines for handling, installation, and operation.

Statutory Requirements

Covers legal obligations and standards for installation and safety.

Technical Data

Installation

Appliance Location

Guidance on selecting the appropriate site and position for boiler installation.

Clearances

Minimum required distances for servicing and maintenance around the boiler.

Appliance Installation

Recommendations Before Installing

Important considerations and checks before proceeding with boiler installation.

General Appliance Information

Safety Valve

Description of the safety valve's function and importance.

Expansion Vessel

Details on the boiler's integral expansion vessel and its capacity.

Boiler Hanging

Hydraulic Connection

Guidance on connecting the boiler's hydraulic and gas systems.

Condensate Trap Connection

Condensate Discharge

Guidelines for safely discharging condensate from the boiler.

Flue Configuration

Electrical Connections

Instructions for making electrical connections to the appliance.

Access to Main Board

Electrical Wiring

Detailed instructions for connecting the boiler to the main electrical supply.

230V Supply and System Controls

Testing Electrical Connections

Procedures for checking electrical system integrity after installation.

Wiring Diagram

Commissioning

Switching On

Procedure for initial power-up and system checks.

Maintenance

Trouble-shooting

Guidance for diagnosing and resolving common appliance issues.

Electrical Installation Check

Steps to verify the electrical system's safety and functionality.

Fault Diagnosis

Draining

Maximum Rate Check and Adjustment

Servicing

Procedures and checks for routine servicing of the appliance.

Combustion Block

Spark Electrode

Removing the Combustion/Door Assembly

Detailed steps for removing the combustion and door assembly.

Heat Exchanger

Procedure for removing and replacing the heat exchanger.

Replacement of Parts

Guidelines for using and fitting genuine Heatline spare parts.

Hydraulic Block

Pump Head Replacement

Gas Valve

Condensate Trap

Instructions for removing, cleaning, and refitting the condensate trap.

PCB Replacement

Main PCB Replacement

Procedure for removing and replacing the main printed circuit board.

User Interface PCB Replacement

Procedure for removing and replacing the user interface printed circuit board.

Manual Handling

Commissioning Checklist

Service Record

Related product manuals