Owner’s Manual
with Installation & Troubleshooting Instructions
For Heat Siphon® Swimming Pool Heat Pumps
All Z & C Series Heat Siphon Models including
220Volt -1 Ph-60 Hz ONLY: C200HP, C250HP, C375HP, C575HP, Z250HP, Z375HP , Z575HP, Z700HP
220Volt -1 Ph-50 Hz ONLY: C200HP50, C250HP50, C375HP50, C575HP50, Z250HP50, Z375HP50 , Z575HP50
220Volt -3 Ph-50/60 Hz: C250HP3, C375HP3, C575HP3, Z250HP3, Z375HP3 , Z575HP3, Z700HP3
380/460 Volt - 3 Phase - 50/60 Hz - C200HPX, C250HPX, C375HPX, C575HPX, Z250HPX, Z375HPX, Z575HPX, Z700HPX
440 Volt - 3 Phase - 60Hz - C575HP4, Z575HP4, Z575HP4, Z700HP4
200,375,575 Series Heat Only Models 575HC and 700HP Series Models

Table of Contents

Questions and Answers

  • M
    Mrs. Christine StevensAug 4, 2025
    What to do if my Heat Siphon Z Series Heat Pump is leaking water?
    • E
      Eric KingAug 4, 2025
      First, determine if the leaking water is normal condensation. Condensation occurs as the unit cools off warm, humid air. To resolve this, turn off your Heat Siphon, keep your pool pump on, and wait until the basepan empties. If the basepan doesn't empty but the leaking stops, it's still condensation, but your drain is blocked. Unclog the barb drain fitting and/or replace the vinyl drain tubing. Test the leaking water for chlorine. If it tests negative, it's condensation. If the water has chlorine and the leak continues, contact your dealer.
  • C
    Claudia BarnettAug 12, 2025
    Why my Heat Siphon Z Series does nothing?
    • G
      Gregory KleinAug 12, 2025
      Several factors could cause this. The air temperature might be too cold; if it's below approximately 42°F, the unit will shut off automatically to prevent icing. Wait for the air temperature to reach 45°F to 48°F for the unit to automatically reset and turn on. Alternatively, a brief power interruption might have activated a time delay. Wait 5 minutes for the unit to restart. Also, check if the breaker is tripped, which could indicate a bad breaker, faulty wiring, loose wires, or a poor connection in the junction box. Have your installer check the wiring and breaker.
  • V
    Victor WellsAug 18, 2025
    What to do if my Heat Siphon Heat Pump tries to start then does nothing?
    • K
      Kelly BakerAug 18, 2025
      This issue can arise from a few causes. A brief power interruption might have activated the time delay. In that case, wait 5 minutes for the unit to restart. If the air temperature is below 45°F to 48°F and the pool water is cold, wait for both to reach 50°F for the unit to restart automatically and resume normal heating. Also, ensure the pool filter is clean and the pool water flow is stable; restore the correct water flow if needed.
  • P
    pauljohnstonAug 27, 2025
    How to troubleshoot a Heat Siphon Z Series Heat Pump that runs but doesn't heat?
    • J
      Jeffrey ZavalaAug 27, 2025
      Several factors could be at play. Check if the air leaving the unit is colder than usual. Also, ensure the pool pump is running long enough each day; run it continuously for 24 hours to determine the required time. If it's still not heating, contact your dealer. Consider whether there's abnormally high heat loss, such as no cover on an extremely windy day. Cover the pool and run the pool pump for 24 hours. If it's still not heating, contact your dealer.

Summary

Owners Section

How Heat Siphon Works

Explains the principle of heat transfer in a Heat Siphon unit.

Use a Qualified Installer

Emphasizes the importance of using a trained and licensed professional for installation.

Plan Your Installation

Covers critical planning steps including sizing, location, and plumbing.

Owner Troubleshooting Guide

Provides steps to diagnose and resolve common operational issues.

Maintenance and Winterizing

Outlines routine upkeep and seasonal preparation for the unit.

Installer Section

Receiving Shipment and Handling

Procedures for inspecting shipments and safely moving the unit.

Planning Installation Location

Specifies ideal physical location, clearance, and prohibited areas.

Plumbing Requirements

Outlines the required PVC pipe size and configuration for connecting the unit.

Electrical Wiring and Safety

Details power requirements, wire sizing, and GFCI protection.

Digital Player Controller Operation

Reading The Player Display

Explains how to interpret the information shown on the digital player display.

Player Operating Modes

Details the different operating modes available for the digital player.

Error and Warning Codes

Provides definitions and explanations for various error and warning codes.

Analog TimerStat Pro Controller

Timerstat Pro Error Codes - Status LED

Explains how to interpret error codes indicated by the status LED on the TimerStat Pro.

Appendix A: Wiring Diagrams

Analog Model Wiring Diagrams

Electrical wiring diagrams for analog TimerStat Pro models.

Digital Model Wiring Diagrams

Electrical wiring diagrams for digital player models.

Appendix D: Spa Heating Issues

WARNING! Water Temperature Safety

Provides crucial safety warnings regarding water temperature in spas and hot tubs.

Thermostat Set Point Depression

Explains thermostat set point depression and how to mitigate it for spa heating.