Do you have a question about the Heat&Glo 6KX-CU and is the answer not in the manual?
Details the certification of the appliance by Underwriters Laboratories, Inc. (UL).
Information regarding the ceramic glass and how to obtain replacement glass.
Table of BTU input ratings and orifice sizes for different models.
Guidelines for reducing input rate at elevations above 2000 feet.
Defines materials that will not ignite or burn, including ASTM E 136 standard.
Defines materials that can ignite and burn, whether flame proofed or not.
Requirements for electrical wiring, grounding, and GFCI protection.
California warning regarding chemicals like benzene and reproductive harm.
Specific installation requirements for Massachusetts, including CO detectors and signage.
Key factors to consider before starting installation, including codes and appliance location.
Recommended clearances for wall surfaces and TVs above the appliance.
List of tools and building supplies required for installation.
Instructions for unpacking and inspecting the appliance and its components.
Table of weights and detailed dimensions for 6KX and 8KX models.
Diagrams and dimensions for various decorative barrier fronts (Portrait, Loft, Forge, Chapel, Studio, Folio).
Guidelines for selecting appliance location and maintaining clearances to combustible materials.
Instructions for building the appliance chase, including firestops and insulation.
Recommendations for protecting vinyl flooring and hearth material placement.
Details on approved venting systems and warnings against mixing components.
Clearances required for vent termination caps to combustibles.
Table of minimum clearances for vent terminals based on location and material.
Information on calculating effects of elbows and their offsets.
General rules and specific diagrams for vent configurations and limitations.
Guidelines for maintaining air space clearance to vent pipes and firestops.
Instructions for framing holes and installing wall shield firestops for vent penetrations.
Requirements for framing openings and installing ceiling firestops.
Instructions for installing an attic insulation shield to prevent overheating.
Steps for preparing the vent collar for top or rear venting installation.
Instructions for preparing the appliance for optional heat management systems.
Procedures for properly squaring, positioning, and securing the appliance.
Information about the factory-installed non-combustible board above the fireplace opening.
Detailed steps for assembling DVP and SLP series vent sections correctly.
Instructions for assembling slip sections, including overlap and screw placement.
Guidelines for supporting vent sections to prevent sagging and separation.
Procedure for safely disassembling vent sections by rotating seams.
Instructions for installing and sealing roof flashing, storm collars, and termination caps.
Requirements for heat shields and installation of horizontal termination caps.
Basic electrical safety, wiring requirements, and potential interference issues.
Detailed wiring instructions for the IntelliFire Touch Ignition System.
Procedures for servicing the fan, including component removal and reinstallation.
Information on fuel type compatibility and conversion procedures by qualified technicians.
Guidelines for gas pressure requirements and testing for optimal performance.
Steps for connecting the gas supply line to the appliance.
Adjustments for installing the appliance at elevations above 2000 feet.
Instructions and guidelines for adjusting the air shutter for proper flame appearance.
Procedures for servicing or replacing the appliance gas valve.
Instructions for replacing the pilot shield on 6KX, 8KX (NG) models.
Guidelines for applying facing and finishing materials, including clearances.
Reference to section 2.B for guidelines on installing a television above the appliance.
Requirements for combustible and non-combustible mantels and wall projections.
Information regarding hearth extensions and vinyl flooring restrictions.
Dimensions and fit types for decorative barrier fronts and finishing methods.
Instructions for removing shipping materials, splatter guards, and finishing strips.
Procedure for cleaning sawdust from the firebox and control cavity.
Step-by-step instructions for installing brick refractory or black glass liner components.
Instructions for installing the burner overlay and checking burner ports.
Procedure for placing the provided stone media for illuminated embers.
Guidelines for placing ember material without blocking burner ports.
Detailed instructions and diagrams for correctly placing logs for different models.
Steps for setting up the IntelliFire Touch control system and remote.
Procedure for safely removing and reinstalling the fixed glass assembly.
Important note on installing approved decorative barrier fronts to prevent contact with hot glass.
List of approved DVP, SLP, and Power Vent components for installation.
List of optional accessories, including remote controls, Wi-Fi modules, and kits.
| Brand | Heat&Glo |
|---|---|
| Model | 6KX-CU |
| Category | Indoor Fireplace |
| Language | English |