EasyManua.ls Logo

Heatcraft Mohave - System and Components Overview; Condensing and Evaporator Unit Features

Heatcraft Mohave
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
Condensing Unit
(Vertical Air Discharge Design)
Standard Features:
• Electronic Hot Gas Defrost Controller includes Defrost Initiation and
Termination Control, Pressure Fan Cycling for Head Pressure Control, Ambient
Fan Cycling Option, Anti-Short Cycling Protection, and Low Pressure Control
• Electronic Pressure Regulator for Defrost Control
• Suction Accumulator
• High Pressure and Redundant Low Pressure Control
• Oil Pressure Safety Control
• High Efficiency Copeland Discus Compressors with POE oil
• Thermally Protected Permanently Lubricated Ball Bearing Condenser Fan
Motors
• Electrical Controls located in easily accessible control box with a hinged cover
• Receivers are sized for sufficient pump down capacity with inlet and outlet
service valves
• Cabinet is constructed from painted galvanized steel
• Convenient Access Panels for easy servicing to internal components
• Suction and Discharge Vibration Eliminators
• Separate Sub-cooling Circuit.
• Replaceable Liquid Line Filter Drier
• Replaceable Core Suction Filter
• Sight Glass
• Compressor Head Fan on L6 Models
• MODBUS RS-485 (Inherent on control board)
Optional Features:
• Head Pressure Valves (ORI/ORD)
• Oil Separator
• Insulated and Heated Receiver
• Fused Disconnect Switch
• Non-fused Disconnect Switch
• Coated Condenser Coils for protection against harsh environments (Consult
factory)
• Phase Loss Monitor
• Mounted Evaporator Control Contactors
• Remote Monitoring (RRC) Wireless Transmitter
• Variable Frequency Drive Package for Condenser Motors (Consult factory)
• Demand Cooling (Required for R-407A, R-407F, R-448A, and R-449A L6
models)
Evaporators
(Medium Profile & High Profile Unit Coolers)
Standard Features:
• All Components are factory installed and wired
• Power Supply Independent from Condensing Unit
• Mounted Fan Control Contactors and Drain Pan Heater Contactors if specified
• Four or Six Fins Per Inch Models
• Mounted TXV and Distributor Nozzle
• Mounted Check Valves
• Mounted Liquid Line Solenoid
• Suction P-Trap
• Thermally Protected Permanently Lubricated Evaporator Fan Motors
• Mounted Electric Drain Pan Heaters
• Insulated Drain Pan (Low Temperature Systems)
Optional Features:
• Mounted Hot Gas Drain Pan Loop
• Evaporator Powered from Condensing Unit
System and Components