For
stranded
wire,
twist
the
fine
strands
tightly
together
and
melt
a
small
amount
of
solder
on
the
bare
wire
ends.
The
wires
are
listed
in
the
order
in
which
they
will
be
used.
Ly
)
Prepare
the
following
wires:
2-1/2”
blue
two
2”
blue
2-1/2"
blue
two
2”
blue
3”
black
stranded
NOTE:
In
the
following
steps,
‘‘S-'’
with
a
number,
such
as
(S-3),
means
to
solder
the
connection.
The
number
following
the
‘’S”
tells
how
many
wires
are
at
the
connection.
(NS)
means
not
to
solder
because
other
wires
will
be
added
later.
Connect
a
2-1/2”
blue
wire
from
switch
SW2
lug
1
(S-1)
to
circuit
board
hole
S
(S-1).
Cs
)
Connect
a
2”
blue
wire
from
switch
SW2
lug
2
(S-1)
to
circuit
board
hole
M
(S-1).
WW)
Connect
a
2”
blue
wire
from
switch
SW2
lug
3
(S-1)
to
circuit
board
hole
N
(S-1).
(i)
Connect
a
2-1/2”
blue
wire
from
switch
SW2
lug
4
(S-1)
to
circuit
board
hole
V
(S-1).
Connect
a
2”
blue
wire
from
switch
SW2
lug
5
(S-1)
to
circuit
board
hole
P
(S-1).
PREPARE
EACH
END
AS
SHOWN
3/4'—
be}
/4"
he
1/2"
114"
—e
AL
~)
¢
|
Xone
CUT
LEAD
OFF
TAKING
CARE
NOT
TO
CUT
THE
SHIELD
LEAD,
REMOVE
THE
OUTER
INSULATION.
<a
(
PEEL
OFF THE
FOIL.
FOIL
=
SHIELD
LEAD
REMOVE
1/4"
OF
THE
INNER
INSULATION.
Detail
1-6A
Refer
to
Detail
1-6A
and
prepare
the
following
lengths
of
small
shielded
cable:
(+)
2-3/4"
3-1
/
At
the
end
of
a
2-3/4”
small
shielded
cable
with
the
shield
lead,
connect
the
inner
lead
to
switch
SW2
lug
6
(S-1)
and
the
shield
lead
to
switch
SW2
lug
7
(NS).
Cd
(:)
Connect
a
2”
blue
wire
from
switch
SW2
lug
7
(NS)
to
circuit
board
hole
NN
(S-1).
Connect
the
inner
lead
at
the
other
end
of
this
cable
to
circuit
board
hole
W
(S-1).
(
)
At
the
end
of
a
3-1/4”
small
shielded
cable
with
the
(_.)
Connect
one
end
of
a
3’’
black
stranded
wire
to
circuit
“shield
lead,
connect
the
inner
lead
to
switch
SW2
lug
9
:
board
hole
R
(S-1).
The
other
end
will
be
connected
(S-1)
and
the
shield
lead
to
switch
SW2
lug
7
(S-3).
later.
The
free
end
of
this
cable
will
be
connected
later.