How to fix low battery power in Heatmaster Indoor Fireplace remote?
- SStephen LeeAug 13, 2025
If your Heatmaster Indoor Fireplace remote has low battery power, the batteries are likely weak and need to be replaced.
How to fix low battery power in Heatmaster Indoor Fireplace remote?
If your Heatmaster Indoor Fireplace remote has low battery power, the batteries are likely weak and need to be replaced.
What to do if Heatmaster HM2-MAN module beeps constantly?
If your Heatmaster Indoor Fireplace module beeps constantly, it could be due to a system cycle off and back on within 30 seconds. To resolve this, cycle the system to off and wait 30 seconds before relighting. Another potential cause is a loose ground wire, so ensure that the ground wire is tight.
Why is there smoke and odor coming from my new Heatmaster Indoor Fireplace?
The slight smoke or odor during the initial operation of your Heatmaster Indoor Fireplace is likely due to residues from manufacturing processes and logs curing. This issue should resolve itself after a few hours of use.
What does it mean when my Heatmaster Indoor Fireplace module beeps 4 times?
If the module of your Heatmaster Indoor Fireplace beeps 4 times every 2 seconds, it indicates that the module's internal temperature has exceeded 170 degrees. To fix this, cycle the system to off and allow the module to cool below 160 degrees.
What does it mean when Heatmaster Indoor Fireplace module beeps twice per second?
If your Heatmaster Indoor Fireplace module beeps twice per second, the pilot has likely been proven and then lost up to 3 times without being reset. The module will beep for 5 minutes. Place the switch in the off position once the beeping has stopped, then reset it to on.
Why is my Heatmaster HM2-MAN beeping once per second?
If the module of your Heatmaster Indoor Fireplace beeps once per second, it indicates that the pilot did not light within the trial period. To resolve this, cycle the on/off switch or remote to off, then reset to on.
Why is the pilot sparking but not igniting on my Heatmaster HM2-MAN Indoor Fireplace?
If the pilot sparks but doesn't ignite on your Heatmaster Indoor Fireplace, several factors could be at play. First, ensure the gas supply is on and the equipment shutoff valve is open. Air in the gas lines can also prevent ignition; try turning the burner system on and off repeatedly to remove the air, which may take several attempts. Check the thermocouple connections at both the control valve (hand tight plus 1/4 to 1/2 turn) and the control module. Also, verify gas flow to the ODS pilot and ensure all shut-off valves are open, checking that the pressure supplied to the valve is correct. A depleted LP gas supply or a disconnected/broken valve cable could also be the cause, ensure that the valve cable is correctly connected. The ODS pilot might be clogged, in which case you should clean ...
| Model | HM2-MAN |
|---|---|
| Category | Indoor Fireplace |
| Brand | Heatmaster |
| Heating Capacity | Up to 1, 500 sq ft |
| Firebox Material | Steel |