Technical Specification
Menu Description Range
1 Temp. Offset -8
0
C ~8
0
C
2 Dead Zone 0
0
C ~3
0
C
3 Set Point Max. 5
0
C ~35
0
C
4 Set Point Min. 5
0
C ~35
0
C
5
NTC Select (Ambient - I, Floor - E) I only, E only, I & E, I or E
6
Low Protection Max. 5
0
C ~10
0
C
7
Low Protection Min. 5
0
C ~10
0
C
8
High Protection Max. 5
0
C ~90
0
C
9
High Protection Min. 5
0
C ~90
0
C
10
Backlight off Time after Operation. 3s~180s
11
Min. Backlight Brightness of Standby Status 1%~100%
12
Relay Delay Time 0s~250s
13
Relay Output Normal(NO);Inverted(NC)
14
Restore << or >>
Parameter settings
To access parameter settings switch the thermostat OFF and immediately
press
for 2 seconds. You can set the desired values by pressing <<
or >> , and go to other pages by pressing Pre or Next. Please note the
upper limit should be no higher than 28
0
C to conform with European
regulations.