22
TROUBLESHOOTING GUIDE
PROBLEM
PROBLEM
PROBLEM
PROBLEM
PROBLEM
THERE IS NO POWER TO THE SAUNA
ONE HEATER DOES NOT WORK
NONE OF THE HEATERS WORK
THE CONTROL PANEL DOES NOT WORK
THE LIGHTS ARE NOT WORKING
• Always unplug the sauna and allow it to cool down before performing any maintenance.
• Repairs to the electrical components of the sauna should only be performed by a qualied
service technician.
• Unauthorized repairs or alterations will void the manufacturer’s warranty.
1. Check that the main power cable is plugged into the wall outlet.
2. Check that the circuit breaker for the outlet has not tripped. If the breaker has
tripped, check that the amperage of the breaker is appropriate for your sauna.
3. Check all connections to the power supply box.
4. Check for damage to the main power cable; replace if necessary.
5. Replace the power supply box, if necessary.
1. Check that all the connections are tight.
2. Replace the heater element.
1. Check that all the connections are tight.
2. Replace the heater circuit board, if necessary.
1. Check that all the connections are tight.
2. If the numbers are scrambled or the buttons are unresponsive, replace the
control panel.
3. If the temperature indicator does not work or reads “–” or “EP”, replace the
control panel.
1. Check that all the connections are tight.
2. If one light does not work, replace the light xture.
3. If neither the lights or the radio are working, replace the power supply box.
Solution
Solution
Solution
Solution
Solution
WARNING!