When the ice basket is full please remove the ice immediately, do not allow the ice basket to overfill.
CLEANING
1. Clean the inner lining, ice basket, water reservoir, ice shovel and evaporator frequently. Before commencing
any cleaning, unplug the unit and remove any ice cubes. Use a diluted solution of water and vinegar to clean
the inside and the outside surface of the Ice Maker. Do not spray Ice Maker with chemicals or diluted agents
such as acids, gasoline or oil. Rinse thoroughly.
2. Keep any ventilation openings of the appliance clear of obstruction. Do not use mechanical devices or other
means to accelerate the defrosting process, other than those recommended by the manufacturer.
3. Reuse the machine after being inactive for a period of time.
4. To ensure the cleanliness of ice, change the water in the water reservoir at least once per day. If you do not
plan on using the Ice Maker for a long time, then completely drain the water from the unit.
5. If the unit stops working due to water shortage, ice fullor interrupted power supply, it will remain off for 3mins
and will resume after 3 minutes has passed.
6. Always use fresh water before starting any ice making.
TROUBLESHOOTING
1. PLEASE NOTE: If a power failure occurs due to disconnection of the power cord, or the off power button has
been pushed during an ice making cycle, small ice chips may form and lodge in the automatic shovel causing it
to jam. If this occurs, the ice chips must be removed by disconnecting the power cord and gently pushing the
shovel to the rear of the cabinet and removing the ice chips, then restarting.
2. Please check if the water reservoir is flat when the ice shovel cannot move the ice to ice basket. If not, please
push the ice shovel gently with your hands, then press the POWER button to restart.
PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTIONS
The compressor works
abnormally with a
buzzing noise.
The voltage is lower than
recommended.
Stop the Ice maker and do not restart until the
voltage is as indicated on the rating plate.
Water shortage indicator
light is on.
1.There is no water
2.The pump is full of air
1. Add water until it reaches MAX fill line.
2. Press POWER button to restart.
Indicator lights are not
on.
Blown fuse / no power Replace fuse / Turn power on.
The ice made is too
large with pieces
sticking together.
1.
water temperature is too
low
2. Ice from previous cycle
was left in the water tray.
1. Select small size.
2. Remove ice after each cycle.
All indicators twinkle
simultaneously.
Water tray is blocked by an
ice cube.
Switch the unit off and unplug the power cord.
Remove the ice which
is blocking the tray. Once
removed plug the power
cord in and press the
POWER button. The machine will start 3mins later.