Page 8
TMG-1200 Instruction Manual
Operation of Counter
This device incorporates an 8-digit counter which uses the sensor signal to count one per stroke.
The operating procedure is described below.
1. Setting of preset value
a) Push the counter setup button to set the device in the preset setup mode. (Black-white
inversion occurs at the highest order digit of the preset set point.)
b) With each push of the setup button, the digit with black-white inversion shifts to the lower
order, so set digits to which you wish to set the set point.
c) Turn the setup dial to set to an arbitrary value. Set digits one by one.
d) After setting all digits, don’t fail to push the counter setup button and bring to the position
of the digit with no black-white inversion (the position at which setting is turned off). 8
th
digit7
th
digit6
th
digit5
th
digit4
th
digit3
rd
digit2
nd
digit1
st
digitsetting Off8
th
digit ….. The digit position shifts with each push of the setup button. Setting the preset
set point to “0” turns off setting, so the preset counter operates as the total counter.
2. Resetting of preset counter
To reset the preset counter to “0”, push the preset counter reset button. In this case, the fault
output cannot be cancelled even when the fault detection signal is being output.
3. Batch counter
The batch counter is a 3-digit total counter to count the number of times that the preset
counter has counted up.
4. Resetting of batch counter
When you wish to reset the batch counter to “0”, push the batch counter reset button. In this
case, the fault output cannot be cancelled even when the fault detection signal is being
output.