EasyManuals Logo

Henkelman Boxer User Manual

Default Icon
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Henkelman Boxer
Quick Start Guide
2
3
1
11
10
5
7 8
4 96
Version 01-’24, nr. 0894795
1. Program display: Shows the selected program.
2. PROG 0 – 9 buon: This is used to select the desired program. You can select 10 dierent programs.
3. REPROG buon: This is used to enable the programming mode. The parameters can be changed using the Cursor
key (4), the – / STOP buon (8) and the + / VACUUM STOP buon (9).
4. Cursor key: This key is used to operate the funcons of the parameter display (6) and funcon display (7).
5. Pump cleaning programme buon: This is used to acvate the pump cleaning programme. Moisture can
condensate in the oil when the pump is running only short cycles or when you are packaging moisture-
containing products. This programme removes moisture from the oil of the vacuum pump. Run the pump
cleaning program daily to prevent moisture damage to your pump.
6. Parameter display: This display shows the current value of the acve funcon during the program cycle or the set value of the
selected funcon when the machine is inacve. A red dot will light up in the boom right if the Vacuum+ opon is enabled.
7. Funcon display: The LED light in front of the funcon lights up if the funcon is acve during the program cycle or
if the funcon is selected in the programming mode.
8. – / STOP buon: This is used to interrupt the enre cycle during a packaging cycle. All funcons are skipped and the
cycle is terminated. In the programming mode, the value of the selected parameter can be lowered using this buon.
9. + / VACUUM STOP buon: This stops the acve funcon and proceeds to the next program step. In the
programming mode, the value of the selected parameter can be increased using this buon.
10. Vacuum meter: Shows the pressure in the vacuum chamber. A value of -1 bar corresponds to 99% vacuum.
11. On/O buon: Serves to turn the control panel on or o.
Start the machine (11) and scroll through the pre-programmed programs (2) and/or pre-programmed sengs (4) to make your sengs.
The display (1) shows the program number and the display (6, 7) shows the programmed values. You can make adjustments by pressing
the REPROG key (3) and using the + and - keys (8, 9) to make changes. When the sengs are nished, save with the REPROG key (3),
place the product in the machine in a suitable seal bag, close the lid and the process will start. For the best end result, we recommend
cooling the product to 2-4°C before packing. This will prevent the product from boiling.
Scan the QR code
to download the
user manual
Prior to the First Use
Carefully read the safety instrucons on the back side of this guide.
Check the oil sight glass to see if the amount of oil in the pump is sucient.
If the amount of oil in the pump is insucient, rell it.
See the user manual for more informaon.
Sample programs
* The vacuum rates listed are for machines with the sensor opon. For me-controlled machines, you need to nd
the best seng yourself, it depends on machine type and product volume.
Type of product Program Vacuum* Seal Soair
Solid products 1 99% 2,2 s OFF
Liquids or products containing liquids 2 97%
99% with Liquid Control (opon)
2,2 s OFF
Fragile or sharp products 3 99% 2,2 s 5 s

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Henkelman Boxer and is the answer not in the manual?

Henkelman Boxer Specifications

General IconGeneral
ModelBoxer
BrandHenkelman
Seal bar length350 mm
Sealing Length350 mm
Frequency50 Hz