for the technician
Installation instructions
Boiler location
INSTALLATION ROOM
When having an heat ouput lower than 35 kw (about 30000 Kcal/h), particular features for the
installation room are not required. Shortly, all installation rules assuring a safe and regular gas
boiler operation, must be strictly respected.
Place here all necessary
advices according to national rules about:
- Installation room requirements
- Limitations in power and/or number of boilers and other
appliances in the same room
Exemple:
Law number XXXX
“Law title and/or brief description”
INSTALLATION IN ROOMS WHERE TEMPERATURE CAN DROP DOWN TO 0°C:
When the installation place does not guarantee an adequate repair against atmospheric agents,
the gas boiler must be completely protected through an adequate coverage as a safety measure
against the above agents.
In case of boiler installation in rooms where temperature can drop down to 0°, it is advisable to
protect the heating circuit with an antifreeze liquid. See the “System Filling” section.
This appliance is not suitable for outdoor installation.
ROOM VENTILATION (
EURA E - natural draught)
When a natural draught boiler is installed, permanent ventilation of the installation
room is mandatory and extremely important. Ventilation must be made and sized in
accordance with Laws and Rules in force.