STANDARD PARAMETERS
The following charts show several parameters used in the dispenser’s operation along with
their respective default values.
Mixing – Time ON
Mixing – Time OFF
Agitation time ON
Agitation time OFF
3 min – 0 sec
120 min – 0 sec
Pump motor acceleration speed
1000
When the value increases
acceleration also increases
Pump motor deceleration speed
1500
When the value increases,
deceleration also increases
Time during which the pump
motor receives the maximum
power
supply
Pump dispensing speed
expressed as a percentage of the
maximum value
70% (300 r.p.m. – 0.3 l/min)
Quantity dispensed during the
purging cycle
Pump speed during the purging
cycle
Number of pump motor steps
during the phase in which the
drop is “pulled up”
Pull-back device – Waiting time
Waiting time, after each
dispense, before the pull-back
cycle is implemented
Below this level you are warned
to fill the canister (yellow)
Below this level dispensing
is no longer permitted (red)
Number of motor steps possible
before proceeding with a
precautionary substitution
1.013.854.085 steps
(1.760,00 litres)
Maximum time allowed without
purging, between two dispense
cycles of the same colorant
Quantity minimum calibrated
The theoretical value moved with one complete rotation of the pump is 0.6944 cc,
measured with water at an approximate temperature of 25 °C.
Dispensing 1 cc of product requires 576.05346 steps of a pump’s stepper motor. This
is the value programmed in the software as being the “standard” calibration value.