EasyManua.ls Logo

HERO A450 - STANDARD PARAMETERS

HERO A450
41 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29
STANDARD PARAMETERS
The following charts show several parameters used in the dispenser’s operation along with
their respective default values.
PARAMETER
MEANING
DEFAULT VALUE
Mixing Time ON
Mixing Time OFF
Agitation time ON
Agitation time OFF
3 min 0 sec
120 min 0 sec
Pumps acceleration
Pump motor acceleration speed
1000
When the value increases
acceleration also increases
Pumps - deceleration
Pump motor deceleration speed
1500
When the value increases,
deceleration also increases
Pumps Boost time
Time during which the pump
motor receives the maximum
power
supply
30 sec
Pumps Start speed
Pump starting speed
15% (75 r.p.m.)
Canister Page
Dispensing speed
Pump dispensing speed
expressed as a percentage of the
maximum value
70% (300 r.p.m. 0.3 l/min)
Purging - ml
Quantity dispensed during the
purging cycle
1 ml/0.5 ml
Purging - Speed
Pump speed during the purging
cycle
25% (125 r.p.m.)
Pull-back device - Steps
Number of pump motor steps
during the phase in which the
drop is pulled up
40 (0,1 r. 0,07 cc)
Pull-back device Waiting time
Waiting time, after each
dispense, before the pull-back
cycle is implemented
3 sec
Capacity
Canister capacity
3 5 liters
Warning level
Below this level you are warned
to fill the canister (yellow)
0.4 litres
Alarm level
Below this level dispensing
is no longer permitted (red)
0.2 litres
Steps alarm
Number of motor steps possible
before proceeding with a
precautionary substitution
1.013.854.085 steps
(1.760,00 litres)
Purging alarm
Maximum time allowed without
purging, between two dispense
cycles of the same colorant
12 hours/24 hours
Calibration Page
Drop Calibration
Quantity minimum calibrated
0.02 ml
Threshold Calibration
Machine Calibration
Variable
The theoretical value moved with one complete rotation of the pump is 0.6944 cc,
measured with water at an approximate temperature of 25 °C.
Dispensing 1 cc of product requires 576.05346 steps of a pump’s stepper motor. This
is the value programmed in the software as being the standard” calibration value.