Details warranty terms, conditions, and exclusions for HERZ boiler systems.
Provides essential safety guidelines for system operation, maintenance, and general precautions.
Explains warning symbols and their meanings related to system handling and hazards.
Covers essential safety principles for operation, installation, and maintenance by qualified personnel.
Emphasizes proper operation and maintenance by qualified personnel, adhering to warnings.
Details general safety instructions for operating the system, including emergency procedures.
Outlines general safety measures and precautions required before starting maintenance work.
Specifies the required properties and quality standards for wood pellets used in the HERZ pelletstar boiler.
Explains the process of fuel transport from the storeroom to the combustion chamber.
Describes the differentiation and control of primary and secondary air supply for combustion.
Details automatic ignition, heat requirement control, and operational temperature limits.
Explains the safety devices like the safety valve and temperature limiter, and their functions.
Outlines the procedure for initial system start-up, including commissioning and operator explanation.
Specifies the operational range for boiler temperature and the importance of return flow temperature.
Discusses consequences of operating at temperatures that are too high or too low.
Explains the procedure for starting the system when the boiler room temperature is low.
Explains modulated operation, burn-out, and burner cleaning phases.
Details heat exchanger cleaning and flame monitoring functions.
Explains frost protection mechanisms and lambda control for optimizing combustion.
Illustrates the temperature manager's function in controlling heat demands of modules.
Details the condition required to switch on the display and the initial startup process.
Shows the main display screen with key values and explains navigation buttons.
Describes interaction with the touch panel and screen navigation.
Details how to enter a code to access settings, change values, and activate tests.
Explains the procedure and conditions for switching the boiler on and off.
Describes how to set and synchronize the date and time using NTP or manually.
Shows how fault messages are displayed and categorized (actual vs. archive).
Lists all available modules (Boiler, Buffer, etc.) and how to navigate their menus.
Displays the main overview screen for the boiler module.
Shows boiler status screens with key parameters and data.
Details settings related to residual heat, hysteresis, power, and fuel.
Displays the general overview screen for the buffer module.
Shows buffer status screens with temperature readings and pump status.
Details settings like winter/summer temperatures and difference temperatures.
Shows general overview screens of the hot water tank module.
Displays status screen for the hot water tank, including temperature and valve settings.
Details settings for must temperature, loading times, and legionella protection.
Shows the general overview screen for the heating circuit module.
Displays status screens for heating circuit, including temperatures and mixer/pump status.
Explains different operating modes for the heating circuit.
Details the time program settings for the time mode.
Displays the overview screen for Solar Program 1.
Shows status screens for Solar Program 1 with key parameters.
Details settings for Solar Program 1, including antifreeze and rotation speed.
Displays the overview screen for the hydraulic compensator.
Shows status screen for hydraulic compensator, including temperatures and pump states.
Details settings for switch on barrier and temperature increase.
Displays the overview screen for the net pump.
Shows status screen for the net pump, including temperatures and pump state.
Details settings for switch on barrier and temperature increase for the net pump.
Displays the overview screen for the zone valve.
Shows status screen for the zone valve, including temperatures and valve state.
Details settings for switch on barrier and temperature increase for the zone valve.
Displays the overview screen for external requirements.
Shows status screen for external requirements, including active demand and analog values.
Details settings for external must temperature and analog must activation.
Details settings for IP address, subnet mask, gateway, and VNC port.
Details Modbus TCP settings like port, timeout, and buffer size for data exchange.
Explains how to configure email settings and add recipients.
Covers configuration of mail server, email address, and port for sending emails.
Explains terms related to the boiler module, such as temperatures, power, and sensors.
Explains terms related to buffer temperatures, switching, and outside temperature.
Explains terms related to hot water tank temperatures, pumps, and valves.
Explains terms related to flow/backflow temperatures, room temperature, and mixer/pump status.
Explains terms for solar module overview, status, and settings (Program 1).
Explains terms related to hydraulic compensator temperature, existing/required temp., and pumps.
Explains terms related to net pump existing/required temperature, switch on barrier, and temp. increase.
Explains terms related to zone valve existing/required temperature, switch on barrier, and temp. increase.
Defines external requirement, digital and analog inputs.
Lists faults related to boiler, combustion room, flue gas, back flow, stoker, and temp. sensors.
Lists faults for circulation, HC sensors, collector sensors, and solar tank sensors.
Lists faults for hydraulic compensator, overheat, solar overheating, and antifreeze conditions.
Lists faults for BFP, ignition, fire out, temperature control, STL, lambda, and empty ash pan.
Lists faults for level sensors, grate cleaning, suction mode, suction valve, and ash container.
Addresses gradual decrease in boiler output due to ash/slag, clogged exchangers, or poor fuel.
Discusses causes for not reaching operating temperature, like fuel quality or low fuel level.
Covers reasons for ash emission, such as dirty fly ash container or high fan speeds.
Outlines weekly inspection of the entire boiler system and fuel store.
Details ash pan and combustion chamber cleaning every 4-10 weeks.
Covers controller operation, fault messages, fan checks, and combustion chamber cleaning.
Details the flow must temperature profile for the screed drying operation mode.
| Fuel Type | Wood pellets |
|---|---|
| Nominal Heat Output | 60 kW |
| Heating capacity | 60 kW |
| Efficiency | 93% |
| Hopper capacity | 300 kg |
| Power supply | 230 V |