NOTE:
·Before use this dehumidifier, please make sure the outlet is opened,
otherwise, this dehumidifier will be overheated.
·Do not stop the machine by unplugging the power cord directly.
When the bucket is full of water, indicator light flashing, please turn
off the unit, remove the bucket and empty it.
Error Codes:
P.07
Note:
·When error happened, error code flashing on display, if there are more
than one error, each error code display in turn, if only one error, the error
code and the current humidity value are displayed alternately.
·When E1,E2 or E4 occurs, the machine can continue to dehumidification;
Buzzer alarm and display the error code. After the power is disconnected
and reconnected, the machine can still be dehumidified. After the alarm,
the humidity of the environment may not continue to be controlled
according to the set humidity.
·When the error occurs, the buzzer will alarm for a few seconds. During
the alarm, press any button to remove the alarm sound.
1
Humidity sensor error
2
Defrost Temperature sensor error
3
Room temperature sensor error
4
Water full alarm
Number
Error code
Error code meaning