HPE MSA 1060/2060/2062 Installation Guide
Part Number: R0Q73-90006
Published: September 2020
Edition: 1
Abstract
This document describes initial hardware setup for HPE MSA 1060/2060/2062 controller enclosures and disk enclosures,
and is intended for use by storage system administrators familiar with servers and computer networks, network
administration, storage system installation and configuration, storage area network management, and relevant protocols.

Table of Contents

Questions and Answers

  • B
    blackemilyAug 14, 2025
    What to do if the Hewlett Packard Enterprise Controller power supply PCM OK LED is off?
    • P
      Patrick BatesAug 14, 2025
      If the power supply module is not receiving adequate power, verify that the power cable is properly connected and check the power source. Also, verify that the PCM is firmly locked into position within the PCM slot. Review event logs for specific information regarding a PCM fault and follow any recommended actions.
  • K
    Kristin HarmonAug 17, 2025
    What to do if the Hewlett Packard Enterprise Controller connected host port Host Link Status LED is off?
    • M
      Miguel KelleyAug 17, 2025
      If the link is down, check cable connections and reseat if necessary. Inspect cables for damage and replace if necessary. Swap cables to determine if the fault is caused by a defective cable and replace the cable if necessary. Verify that the switch, if any, is operating properly. If possible, test with another port. Verify that the HBA is fully seated, and that the PCI slot is powered on and operational. Review event logs for indicators of a specific fault in a host data path component and follow any recommended actions.
  • S
    samantha23Aug 21, 2025
    What to do if the Hewlett Packard Enterprise HPE MSA 1060 Controller connected port Network Port Link Status LED is off?
    • S
      Susan HensonAug 21, 2025
      If the link is down, check cable connections and reseat if necessary. Inspect cables for damage and replace if necessary. Swap cables to determine if the fault is caused by a defective cable and replace the cable if necessary. Verify that the switch, if any, is operating properly. If possible, test with another port. Verify that the HBA is fully seated, and that the PCI slot is powered on and operational. Review event logs for indicators of a specific fault in a network component and follow any recommended actions. Use standard networking troubleshooting procedures to isolate faults on the network.
  • R
    Robert AndrewsAug 25, 2025
    What does it mean if the Hewlett Packard Enterprise Controller enclosure front panel Fault/Service Required LED is amber?
    • C
      christinewilliamsonAug 25, 2025
      If a fault condition exists or occurred, check the LEDs on the back of the controller enclosure to narrow the fault. Check the event log for specific information regarding the fault and follow any recommended actions. If installing an IOM FRU, try removing and reinstalling the new IOM and check the event log for errors. If the above actions do not resolve the fault, isolate the fault.
  • J
    John SalinasAug 27, 2025
    What to do if the Hewlett Packard Enterprise HPE MSA 1060 Controller connected host port Expansion Port Status LED is off?
    • S
      Samantha WeissAug 28, 2025
      If the link is down, check cable connections and reseat if necessary. Inspect cables for damage and replace if necessary. Swap cables to determine if the fault is caused by a defective cable and replace the cable if necessary. Review event logs for indicators of a specific fault in a host data path component and follow any recommended actions.
  • E
    everettjessicaAug 31, 2025
    What to do if the Hewlett Packard Enterprise HPE MSA 1060 Controller enclosure rear panel Fault/Service Required LED is amber?
    • K
      Kathryn FordAug 31, 2025
      If a hardware-controller power-up error, cache flush error, or cache self-refresh error occurred, restart the controller from the other controller using the SMU or CLI. If the above action does not resolve the fault, remove the controller module and reinsert it.
  • M
    Michael SanchezSep 3, 2025
    What to do if the Hewlett Packard Enterprise HPE MSA 1060 enclosure rear panel FRU OK LED is off?
    • J
      Jeffrey GardnerSep 3, 2025
      If the controller module is not powered on or has failed, verify the controller module is fully inserted and latched in place, and that the enclosure is powered on. Check the event log for specific information regarding the failure.
  • R
    Richard BarnesSep 6, 2025
    How to correct enclosure IDs on a Hewlett Packard Enterprise HPE MSA 1060 Controller?
    • J
      Janice BurtonSep 6, 2025
      To correct enclosure IDs, make sure that both controllers are up, and perform a rescan using the SMU or the CLI.
  • J
    Jason SotoSep 10, 2025
    How to stop I/O on a Hewlett Packard Enterprise Controller?
    • B
      Brittany JeffersonSep 10, 2025
      To stop I/O, stop I/O to all volumes in the pool with the affected disk group, from all hosts and remote systems as a data protection precaution. It is also recommended to conduct regularly scheduled backups of your data.

Summary

1 Overview

MSA 1060;2060;2062 Storage Models

Describes the different MSA storage enclosure configurations and disk support.

MSA 1060;2060;2062 Enclosure User Interfaces

Explains the SMU and CLI as management interfaces for enclosures.

MSA 1060;2060;2062 Controllers

Details the host interface protocols supported by controller modules.

2 Components

Front Panel Components

Describes the front panel elements, including bezels and LEDs.

Disks Used in Storage Enclosures

Details the types of disks supported by MSA 2060 and MSA 1060 enclosures.

3 Installing the Enclosures

Installation Checklist

Outlines the sequential steps for installing enclosures and initial configuration.

FDE Considerations

Explains requirements and considerations for using Full Disk Encryption (FDE).

Connecting Controller and Disk Enclosures

Describes cabling requirements for connecting controller and disk enclosures.

Powering On;Powering Off

Provides the procedure for powering the storage system on and off.

4 Connecting Hosts

Host System Requirements

Details the requirements for data hosts connecting to the storage system.

Host Interface Protocols

Explains Fibre Channel, iSCSI, and SAS protocols for host connections.

About Data Host Connection

Defines initiators and describes direct attach and switch-connect configurations.

5 Connecting to the Controller CLI Port

Device Description

Introduces the CLI port for direct system configuration and management.

Emulated Serial Port

Explains the serial port emulation for connecting to the CLI via USB.

Preparing a Linux System for Cabling to the CLI Port

Details steps for preparing a Linux system to connect to the CLI port.

Preparing a Windows System for Cabling to the CLI Port

Details steps for preparing a Windows system to connect to the CLI port.

Obtaining IP Values

Describes methods for obtaining and setting IP addresses for network ports.

6 Basic Operation

Accessing the SMU

Guides on accessing the web-based Storage Management Utility (SMU).

Configuring and Provisioning the Storage System

Explains how to configure and provision the storage system using the SMU.

7 Troubleshooting

USB CLI Port Connection

Addresses issues with connecting to the controller via the USB CLI port.

Fault Isolation Methodology

Presents the basic methodology for locating faults within the storage system.

Options Available for Performing Basic Steps

Lists options like SMU, CLI, and LEDs for fault isolation.

Performing Basic Steps

Details gathering fault info, determining fault location, and reviewing logs.

8 Support and Other Resources

Accessing Hewlett Packard Enterprise Support

Provides contact information and resources for technical support.

Accessing Updates

Guides on how to download and install software and firmware updates.

A LED Descriptions

Front Panel LEDs

Describes front panel LEDs for enclosures, including bezel and hubcaps.

Controller Enclosure Rear Panel LEDs

Details rear panel LEDs for controller modules (FC, iSCSI, SAS) and PCMs.

Disk Enclosure Rear Panel LEDs

Describes rear panel LEDs for expansion modules and drive enclosures.

B Specifications and Requirements

Safety Requirements

Outlines safety precautions for system installation and handling.

Site Requirements and Guidelines

Provides guidelines for selecting an installation site and preparing the environment.

Site Wiring and AC Power Requirements

Details requirements for AC power supply, wiring, and connections.

Site Wiring and DC Power Requirements

Details requirements for DC power supply, wiring, and connections.

Weight Guidelines

Provides guidelines for lifting and handling enclosures based on weight.

Electrical Guidelines

Outlines electrical precautions and considerations for system installation.

Ventilation Requirements

Specifies minimum clearances for adequate airflow and cooling.

Cabling Requirements

Provides guidelines for routing and managing power and interface cables.

Management Host Requirements

Details requirements for the management host used for initial setup.

Physical Requirements

Specifies dimensions and weights for rackmount enclosures.

Environmental Requirements

Lists technical specifications for operating and non-operating environments.

C Electrostatic Discharge

Preventing Electrostatic Discharge

Lists precautions to prevent damage from static electricity.

Grounding Methods to Prevent Electrostatic Discharge

Describes various methods for grounding ESD-sensitive parts.

D SAS Fanout Cable Option

Locate the SAS Fanout Cable

Guides on how to locate and enable SAS fanout cable support using the SMU.

Hewlett Packard Enterprise HPE MSA 1060 Specifications

General IconGeneral
Controller TypeDual Controller
Maximum Drives Supported96
Supported Drive TypesSAS, SATA
RAID Levels0, 1, 5, 6, 10
Form Factor2U
ProcessorDual-core 1.2 GHz