HPE MSA 1060/2060/2062 Installation Guide
Part Number: R0Q73-90006
Published: September 2020
Edition: 1
Abstract
This document describes initial hardware setup for HPE MSA 1060/2060/2062 controller enclosures and disk enclosures,
and is intended for use by storage system administrators familiar with servers and computer networks, network
administration, storage system installation and configuration, storage area network management, and relevant protocols.

Table of Contents

Questions and Answers

  • J
    jacob75Aug 14, 2025
    What to do if the Hewlett Packard Enterprise Controller power supply PCM OK LED is off?
    • N
      Nancy RayAug 14, 2025
      If the power supply module is not receiving adequate power, verify that the power cable is properly connected and check the power source. Also, verify that the PCM is firmly locked into position within the PCM slot. Review event logs for specific information regarding a PCM fault and follow any recommended actions.
  • R
    ryanrichardsonAug 17, 2025
    What to do if the Hewlett Packard Enterprise HPE MSA 2062 Controller connected host port Host Link Status LED is off?
    • J
      Joseph HernandezAug 17, 2025
      If the link is down, check cable connections and reseat if necessary. Inspect cables for damage and replace if necessary. Swap cables to determine if the fault is caused by a defective cable and replace the cable if necessary. Verify that the switch, if any, is operating properly. If possible, test with another port. Verify that the HBA is fully seated, and that the PCI slot is powered on and operational. Review event logs for indicators of a specific fault in a host data path component and follow any recommended actions.
  • E
    Edward ParkerAug 21, 2025
    What to do if the Hewlett Packard Enterprise HPE MSA 2062 connected port Network Port Link Status LED is off?
    • F
      Francis MendozaAug 21, 2025
      If the link is down, check cable connections and reseat if necessary. Inspect cables for damage and replace if necessary. Swap cables to determine if the fault is caused by a defective cable and replace the cable if necessary. Verify that the switch, if any, is operating properly. If possible, test with another port. Verify that the HBA is fully seated, and that the PCI slot is powered on and operational. Review event logs for indicators of a specific fault in a network component and follow any recommended actions. Use standard networking troubleshooting procedures to isolate faults on the network.
  • S
    Sarah HartmanAug 25, 2025
    What does it mean if the Hewlett Packard Enterprise HPE MSA 2062 enclosure front panel Fault/Service Required LED is amber?
    • Z
      zalvarezAug 25, 2025
      If a fault condition exists or occurred, check the LEDs on the back of the controller enclosure to narrow the fault. Check the event log for specific information regarding the fault and follow any recommended actions. If installing an IOM FRU, try removing and reinstalling the new IOM and check the event log for errors. If the above actions do not resolve the fault, isolate the fault.
  • A
    angela47Aug 28, 2025
    What to do if the Hewlett Packard Enterprise Controller connected host port Expansion Port Status LED is off?
    • M
      Matthew GrantAug 28, 2025
      If the link is down, check cable connections and reseat if necessary. Inspect cables for damage and replace if necessary. Swap cables to determine if the fault is caused by a defective cable and replace the cable if necessary. Review event logs for indicators of a specific fault in a host data path component and follow any recommended actions.
  • T
    townsendjoshuaAug 31, 2025
    What to do if the Hewlett Packard Enterprise Controller enclosure rear panel Fault/Service Required LED is amber?
    • C
      Christine Little DVMAug 31, 2025
      If a hardware-controller power-up error, cache flush error, or cache self-refresh error occurred, restart the controller from the other controller using the SMU or CLI. If the above action does not resolve the fault, remove the controller module and reinsert it.
  • P
    Parker BrownSep 3, 2025
    What to do if the Hewlett Packard Enterprise HPE MSA 2062 Controller enclosure rear panel FRU OK LED is off?
    • Q
      qwalkerSep 3, 2025
      If the controller module is not powered on or has failed, verify the controller module is fully inserted and latched in place, and that the enclosure is powered on. Check the event log for specific information regarding the failure.
  • J
    Juan WilsonSep 7, 2025
    How to correct enclosure IDs on a Hewlett Packard Enterprise HPE MSA 2062?
    • L
      Lucas RivasSep 7, 2025
      To correct enclosure IDs, make sure that both controllers are up, and perform a rescan using the SMU or the CLI.
  • J
    Jeffrey RamirezSep 10, 2025
    How to stop I/O on a Hewlett Packard Enterprise HPE MSA 2062 Controller?
    • J
      Julie ReedSep 12, 2025
      To stop I/O, stop I/O to all volumes in the pool with the affected disk group, from all hosts and remote systems as a data protection precaution. It is also recommended to conduct regularly scheduled backups of your data.

Summary

Overview of HPE MSA Storage

Controller Capabilities and Protocols

Describes controller capabilities and host interface protocols.

Installing HPE MSA Enclosures

Installation Checklist

Step-by-step guide for installing enclosures and initial system configuration.

Powering On and Off

Outlines the procedure for powering the system on and off.

Connecting Hosts to HPE MSA Storage

Connecting to the Controller CLI Port

IP Address Configuration via CLI

Covers obtaining and setting IP addresses using the CLI port.

Basic Operation of HPE MSA Storage

Accessing the SMU

Provides instructions for accessing the Storage Management Utility (SMU).

System Configuration and Provisioning

Guides on configuring and provisioning the storage system using the SMU.

Troubleshooting HPE MSA Storage

Fault Isolation Methodology

Outlines the basic methodology for locating faults within the storage system.

Connection Troubleshooting

Steps to troubleshoot host and expansion port connection issues.

LED Descriptions

Electrostatic Discharge (ESD) Prevention

Hewlett Packard Enterprise HPE MSA 2062 Specifications

General IconGeneral
Controller TypeDual Controller
Maximum Number of Drives192
RAID Levels Supported0, 1, 5, 6, 10, 50, 60
Product TypeStorage Controller
Form Factor2U
Supported DrivesSAS, SATA
Host InterfacesiSCSI, Fibre Channel
Number of Host Ports4
Power SupplyRedundant power supplies