HPE MSA 1060/2060/2062 Installation Guide
Part Number: R0Q73-90006
Published: September 2020
Edition: 1
Abstract
This document describes initial hardware setup for HPE MSA 1060/2060/2062 controller enclosures and disk enclosures,
and is intended for use by storage system administrators familiar with servers and computer networks, network
administration, storage system installation and configuration, storage area network management, and relevant protocols.

Table of Contents

Questions and Answers

  • D
    Dr. Joshua Carter DDSAug 14, 2025
    What to do if the Hewlett Packard Enterprise Controller power supply PCM OK LED is off?
    • T
      Thomas AndersonAug 15, 2025
      If the power supply module is not receiving adequate power, verify that the power cable is properly connected and check the power source. Also, verify that the PCM is firmly locked into position within the PCM slot. Review event logs for specific information regarding a PCM fault and follow any recommended actions.
  • B
    Brian AdamsAug 18, 2025
    What to do if the Hewlett Packard Enterprise HPE MSA 2060 connected host port Host Link Status LED is off?
    • L
      lisa32Aug 18, 2025
      If the link is down, check cable connections and reseat if necessary. Inspect cables for damage and replace if necessary. Swap cables to determine if the fault is caused by a defective cable and replace the cable if necessary. Verify that the switch, if any, is operating properly. If possible, test with another port. Verify that the HBA is fully seated, and that the PCI slot is powered on and operational. Review event logs for indicators of a specific fault in a host data path component and follow any recommended actions.
  • C
    Christopher RichardsAug 21, 2025
    What to do if the Hewlett Packard Enterprise Controller connected port Network Port Link Status LED is off?
    • M
      Mr. Eric Ashley PhDAug 21, 2025
      If the link is down, check cable connections and reseat if necessary. Inspect cables for damage and replace if necessary. Swap cables to determine if the fault is caused by a defective cable and replace the cable if necessary. Verify that the switch, if any, is operating properly. If possible, test with another port. Verify that the HBA is fully seated, and that the PCI slot is powered on and operational. Review event logs for indicators of a specific fault in a network component and follow any recommended actions. Use standard networking troubleshooting procedures to isolate faults on the network.
  • R
    Rhonda RogersAug 25, 2025
    What does it mean if the Hewlett Packard Enterprise Controller enclosure front panel Fault/Service Required LED is amber?
    • B
      Brandon NelsonAug 25, 2025
      If a fault condition exists or occurred, check the LEDs on the back of the controller enclosure to narrow the fault. Check the event log for specific information regarding the fault and follow any recommended actions. If installing an IOM FRU, try removing and reinstalling the new IOM and check the event log for errors. If the above actions do not resolve the fault, isolate the fault.
  • H
    Heather HortonAug 28, 2025
    What to do if the Hewlett Packard Enterprise Controller connected host port Expansion Port Status LED is off?
    • L
      Lori ShawAug 28, 2025
      If the link is down, check cable connections and reseat if necessary. Inspect cables for damage and replace if necessary. Swap cables to determine if the fault is caused by a defective cable and replace the cable if necessary. Review event logs for indicators of a specific fault in a host data path component and follow any recommended actions.
  • L
    Linda HarmonAug 31, 2025
    What to do if the Hewlett Packard Enterprise HPE MSA 2060 Controller enclosure rear panel Fault/Service Required LED is amber?
    • E
      Edward AllenSep 1, 2025
      If a hardware-controller power-up error, cache flush error, or cache self-refresh error occurred, restart the controller from the other controller using the SMU or CLI. If the above action does not resolve the fault, remove the controller module and reinsert it.
  • K
    Katherine JohnstonSep 4, 2025
    What to do if the Hewlett Packard Enterprise HPE MSA 2060 Controller enclosure rear panel FRU OK LED is off?
    • W
      wcarpenterSep 4, 2025
      If the controller module is not powered on or has failed, verify the controller module is fully inserted and latched in place, and that the enclosure is powered on. Check the event log for specific information regarding the failure.
  • X
    Xavier RiveraSep 6, 2025
    How to correct enclosure IDs on a Hewlett Packard Enterprise Controller?
    • J
      James AllenSep 7, 2025
      To correct enclosure IDs, make sure that both controllers are up, and perform a rescan using the SMU or the CLI.
  • S
    Shaun PhillipsSep 12, 2025
    How to stop I/O on a Hewlett Packard Enterprise Controller?
    • E
      Erica CruzSep 12, 2025
      To stop I/O, stop I/O to all volumes in the pool with the affected disk group, from all hosts and remote systems as a data protection precaution. It is also recommended to conduct regularly scheduled backups of your data.

Summary

Overview

MSA 1060;2060;2062 Storage models

Describes the MSA 1060/2060/2062 storage enclosures and disk configurations.

Components

Installing the enclosures

Installation checklist

Outlines the steps for installing enclosures and initial configuration.

Connecting controller and disk enclosures

Details cabling requirements for connecting controller and disk enclosures.

Powering on;powering off

Provides procedures for powering the system on and off.

Connecting hosts

Host system requirements

Lists requirements for data hosts connecting to MSA storage systems.

Connecting to the controller CLI port

Basic operation

Accessing the SMU

Instructions on how to access the Storage Management Utility.

Configuring and provisioning the storage system

Guides on configuring and provisioning the storage system.

Troubleshooting

Fault isolation methodology

Outlines the basic methodology for isolating faults within the storage system.

Isolating a host side connection fault

Details troubleshooting steps for host connection issues with FC and iSCSI ports.

Electrostatic discharge

Preventing electrostatic discharge

Precautions to prevent damage from static electricity when handling components.

Grounding methods to prevent electrostatic discharge

Methods for grounding equipment to prevent ESD damage.

Hewlett Packard Enterprise HPE MSA 2060 Specifications

General IconGeneral
Maximum Number of Drives192
RAID Levels0, 1, 5, 6, 10, 50, 60
Form Factor2U
Controller TypeDual controller
Host ConnectivityiSCSI, Fibre Channel
Supported Drive TypesSAS, SATA
Management InterfaceCLI
Product TypeStorage Controller
Data Transfer Rate12 Gbps SAS
Host InterfaceSAS, Fibre Channel, iSCSI
Drive Bays24
Power SupplyDual redundant power supplies