Measurement
Meter connection
Single-phase two-wire meter is wired with L1 and N.
The single-phase three-wire meter is divided into two types. The zero-line
enters and doesn’t enter to the meter. The wiring point in previous type is
the L1+L2+N connection mode, and the wiring point in behind type is
L1+L2 connection mode.
Two-phase three-wire meter wired with L1+L2+N
Energy measurement
Register: Import active energy(+A), export active energy(-A)
Measurement mode: +A=A_++ A_-;-A= A_-
Range: 000000.00999999.99kWh
Instantaneous measurement
Voltage
Current
Active power
Power factor
Frequency
Temperature
Frozen data
Daily frozen content and capacity
No.
Data
Storage capacity
1
Total import active energy +A
Single meters
daily data for 31
days
2
Total export active energy -A
3
Payment mode(prepayment or post payment)