Harrington Generators International
5HRD Diesel Generator 498-1052
Specifi cation
Engine
Engine model: Kohler KDI 2204 M
Service Interval: 500 hours
Engine Speed: 1500 rpm
Engine Cooling: Water cooled
Starting Method: Electric Start
Specifi c Fuel Consumption 220 g / kW h
Electrical System: 12V DC system
Emissions Level: European Stage 3 A.
Lowest starting temperature: -15°C with standard glow plugs without extra aids
Alternator
Alternator Model: ECP28-VL/4
ECP32-3S/4
Alternator Performance: 30 / 19.0 kVA 4-pole Class H with
AVR
2.5 / 28kVA 12-wire 4-pole Class H
with AVR
Fuel System
Fuel Tank Capacity: 150 litres
Fuel Tank Bund: Yes
Run Time at 100% load app. 22 hrs. Consumption at 100% load
6.8 l / hr
Run Time at 75% load app. 29 hrs. Consumption at 75% load 5.1 l / hr
Run Time at 50% load app. 44 hrs. Consumption at 50% load 3.4 l / hr
Canopy
Canopy Type: Canopied set with integral bunded fuel tank.
Material:
Base: Structural Steel.
Canopy: Smooth galvanised steel.
Finish:
Base: Iron phosphate pre-treatment, zinc rich primer then architectural
grade powder coating.
Canopy: Iron phosphate pre-treatment then architectural grade powder
coating.
Colour:
Base: RAL9005 Jet Black (Semi-Gloss)
Canopy: RAL5013 Cobalt Blue* or RAL9016 Arctic White
Panel: RAL5013 Cobalt Blue* or RAL9005 Jet Black
Doors: Hinged doors
Catches:
Catches have keyed locks (but locks do not have to be used).
Catches have hasps for padlocks.
Lifting:
With forklift from below using integral fork lift pods.
With single point lifting beam with concealed lifting eye.
With slings below and a spreader frame above.
Fixing Down: Through skid tubes underneath the base.
Towing: Towing tube for fi nal adjustment on site
Other: Remote Start and USB Controller Program Socket on Control Panel.