Application field
Smart home
Instrumentation
Wi-Fi Remote monitoring/control
Toy field
Color LED control
Intelligent integrated management of fire protection and security
Smart card terminals, wireless POS machines, handheld devices, etc.
2.
Electrical parameters
Working voltage
Parameter
Smallest
Typical Max
Unit
Working voltage
3
3.3
3.6
V
I/O Voltage
3
3.3
3.6
V
Peak module current
1000mA
800
mA
Supply current
requirements
≥1500
mA
Power supply ripple
requirements
≤50
mV
Table 2. Module power supply requirements