Abnormalities
Key checking points and trouble shooting
Plug the power cord and press the “ON/OFF” key,
but the indicator and display do not light up.
code of failure
* Is the temperature of the oil too high when frying dishes?
* Is the temperature of the surroundings very high?
* Is the air inlet or air outlet of the induction cooker blocked?
* Is the default heating time of the induction cooker ove
r?
* The self-safety protection of the induction cooker starts, wait
for several minutes and connect power to use it.
E1
E2
E3
E4
E5
E6
E7
E8
EA
The main sensor is open circuit. If keep abnormal, please take the appliance to a repairing
and maintenance site to be fixed.
EB
EC
Instruction
Voltage range:
Low voltage protection:80± 10V Low voltage recovery: 90± 10V
High voltage protection:140± 10V High voltage recovery: 130± 10V
14
TROUBLE SHOOTING
Emergency
During use if there are some abnormal cases, please unplug immediately and
disconnect power.
The “ON/OFF” indicator lights up and the display
works normally, but heating does not start.
Heating suddenly stops during the process.
* Is the power plug properly connected?
* Is the switch, power outlet, fuse or power cord
damaged?
* Is the cookware compatible. Refer to page 13.
* For other causes, please take the appliance to a
repairing and maintenance site to be fix
ed.
The main sensor is short circuit. If keep abnormal, please take the appliance to a repairing and
maintenance site to be fixed.
The main sensor is hot. Is the ceramic plate hot ? If it ile it is cool it will recover normal. is, wh ,
If keep abnormal, please take the appliance to a repairing and maintenance site to be fixed.
The IGBT sensor is open circuit. If keep abnormal, please take the applianc
e to a repairing and
maintenance site to be fixed.
The IGBT sensor is short circuit. If keep abnormal, please take the appliance to a repairing and
maintenance site to be fixed.
The IGBT sensor is hot. Is the heat dissipation poor? If it is, while it is cool it will recover normal. ,
If keep abnormal, please take the appliance to a repairing and maintenance site to be fixed.
The voltage is lower, che
ck the voltage. If keep abnormal, please take the appliance to a
repairing and maintenance site to be fixed.
The voltage is higher, check the voltage. If keep abnormal, please take the appliance to a
repairing and maintenance site to be fixed.
Dry burning protect, check it. If keep abnormal, please take the appliance to a repairing and
maintenance site to be fixed.
The main sensor is invalid.
If keep abnormal, please take the appliance to a repairing and
maintenance site to be fixed.
The fan is abnormal. If keep abnormal, please take the appliance to a repairing and maintenance
site to be fixed.