DS-K4H250/450/258 series magnetic lock
connect to DS-K2600 series Access Controller
Step 4:
Enter Access Control Advanced Function Access Control Parameters interface, set Door
Magnetic Sensor as Remian Open, and it should be consistent with the wiring of Door Magnetic
Singnal Output;
Step 5:
Enter Status Monitor Door Status interface, open the door, check door status on iVMS-4200 Client
and the magnetic lock LED status;
NOTE:
Abnomal in Magnetic lock LED status part could be displaied in following scenario, open door
timeout, abnomally open door(by force), as well as not standard installation cuasing armature plate and
lock body contact are not fully fitted.