Operaon Cauon and Device Maintenance
- All the electronic operaon should be strictly compliance with the electrical safety regulaons, fire prevenon regulaons and other related
regulaons in your local region.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnesm radiaon. Avoid the equipment
installaon on vibraons surface or places subject to shock (ignorance can cause equipment damage).
- Please make sure that the power has been disconnected before you wire, install or dismantle the device.
- If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then please contact the service
center.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnesm radiaon. Avoid the equipment
installaon on vibraons surface or places subject to shock (ignorance can cause equipment damage).
- Do not place the device in extremely hot (refer to the specificaon of the device for the detailed operaon temperature), cold, dusty or
damp locaons, and do not expose it to high electromagnec radiaon.
- The device for indoor use shall be kept from rain and moisture.
Exposing the equipment to direct sun light, low venlaon or heat source such as heater or radiator is forbidden (ignorance can cause fire
danger).
- Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a malfuncon however), and
affecng the endurance of sensor at the same me.
- Improper use or replacement of the baery may result in hazard of explosion. Replace with the same or equivalent type only. Dispose of
used baeries according to the instrucons provided by the baery manufacturer.
- Do not expose the device to the corrosive gas. Otherwise the equipment damage may occur.
- Do not expose the device to the explosive situaon.
Panic Alarm Press the buon to trigger the alarm while in emergency condion. The LED keeps red for 2 s.
Medical Alarm
Set the panic buon as medical buon via the AX PRO client. Press the buon to trigger the
alarm while in emergency condion. The LED keeps red for 2 s.
Panic Alarm
Press the two buons synchronously to trigger the alarm while in emergency condion. The LED
keeps red for 2 s.
Medical Al
arm
Set the panic buon as medical buon via the AX PRO client. Press the two buons
synchronously to trigger the alarm while in emergency condion. The LED keeps red for 2 s.
3
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
Funcon
Zone Type
Enable Silent Zone
Slide to green to make the zone keep
silent while alarm is triggered.
Select the zone type of the detector.
Descripon
You can view the device status including temperature, signal intensity,baery level, connecon, 24-hour zone, and operaon mode on the device page.
Tap the buon to enter the sengs page.
Cross Zone
Link Camera
If the alarm triggered in both of the linked zones within
the set me, two alarm messages will be reported.
Polling Rate
Set the interval of heartbeat.
Link with a camera for intruder verificaon.
Accidental Press Protecon
Set the protecon mode to prevent
from false alarm.
Remove the baery. Hold any buon for 8 seconds and meanwhile put the baery in . The red LED flashes 3 mes when the format-
ng is completed.