What does 'B-01 (xx) WLs LOW BATT' mean on HIKVISION Pyronix EURO 46 V10 Security System?
- DdrewhallSep 15, 2025
If your HIKVISION Security System displays 'B-01 (xx) WLs LOW BATT', replace the battery on the radio siren mentioned.
What does 'B-01 (xx) WLs LOW BATT' mean on HIKVISION Pyronix EURO 46 V10 Security System?
If your HIKVISION Security System displays 'B-01 (xx) WLs LOW BATT', replace the battery on the radio siren mentioned.
What to do if HIKVISION Pyronix EURO 46 V10 Security System shows 'KEYS LOCKED OUT'?
If your HIKVISION Security System displays 'KEYS LOCKED OUT', it could be due to: * More than one device connected at the same address: Ensure correct addressing to avoid overlaps, then power the system down and back up. * Too many incorrect key presses: Wait 90 seconds for the keypad to be reintroduced onto the system.
What does 'MAINS FAIL' mean on my HIKVISION Security System?
If your HIKVISION Security System shows a 'MAINS FAIL' message, it means the system detects that the mains frequency and voltage are out of specification. Note that the ‘AC FAIL’ timer is active.
What does 'BATTERY FAULT' mean on my HIKVISION Pyronix EURO 46 V10 Security System?
If your HIKVISION Security System shows 'BATTERY FAULT', this is normal during recharge after a mains failure.
How to fix 'I-01 (xx) WLs SUPERVN' on HIKVISION Pyronix EURO 46 V10 Security System?
If your HIKVISION Security System displays 'I-01 (xx) WLs SUPERVN', perform a walk test on the detector and a diagnostic signal strength test, then try replacing the battery.
How to troubleshoot 'Input (xx) Wirles Poll Fail' on HIKVISION Pyronix EURO 46 V10 Security System?
If your HIKVISION Security System displays 'Input (xx) Wirles Poll Fail', test the signal strength and battery status for each wireless device, especially the one that corresponds to the input named by the fault message.
How to resolve 'Error some Areas cannot be unset' on HIKVISION Pyronix EURO 46 V10?
If your HIKVISION Security System displays 'Error some Areas cannot be unset', you must adjust the programming before exiting Engineer mode.
How to fix 'Engineer Access Denied' on HIKVISION Security System?
If your HIKVISION Security System displays 'Engineer Access Denied', ensure that ALL areas are unset, using suitable user codes/tags at the appropriate keypads/readers.
How to fix 'Authorisation Required' on HIKVISION Pyronix EURO 46 V10 Security System?
If your HIKVISION Security System displays 'Authorisation Required', the 'Allow Engineer Menu' option needs to be enabled by the master manager.
What does 'BAT LOAD FAIL' mean on my HIKVISION Pyronix EURO 46 V10 Security System?
If your HIKVISION Security System displays 'BAT LOAD FAIL', and the option is selected, it means the battery is uncharged or its capacity is below specification, and it may need replacing.
Zones | 46 |
---|---|
Wired zones on board | 8 |
Keypads | Up to 4 |
Areas | 4 |
Operating Temperature | -10°C to +40°C |
Type | Control Panel |
Outputs | 4 |
Communication | PSTN |
Radio frequency | 868MHz |
Backup battery | 7Ah |
Product Type | Security System |
Manages learning and deleting wireless inputs, bells, and arming stations.
Configures input types, areas, and attributes.
Details attributes like Chime, Omittable, Double Knock, etc., for inputs.
Configures input resistance, EOL mode, and response time.
Guides the process of enabling and configuring ZEMs on the EURO system.
Configures the programming of outputs on the EURO 46 V10.
Ensures keypads and readers are correctly addressed and configured.
Configures various site-specific behaviors and fault handling.
Defines how the system exits, e.g., Timed, Final Door, Push to Set.
Allows viewing and analyzing panel and access control logs.
Enables testing of all programmed inputs on the system.
Analyzes wireless device signal strength as a percentage.
Measures battery levels for wireless devices and provides status.
Explains how to set up uploading/downloading via InSite software.
Resets the panel settings to default, including deleting wireless data, codes, and logs.
Lists options for addressing, language, zone status, volume, and reset.
Details the steps for connecting the panel to InSite software via the cloud.
Guides on configuring the PC software for cloud connection.
Steps to configure the panel for RS232 connection.
Steps to configure the PC software for RS232 connection.
Identifies faults related to devices not installed or lost from the bus.
Details troubleshooting for communications faults (Modem, Line, ARC).
Addresses issues with wired devices on the RS485 bus.
Covers faults like Case Tamper and Code Guessing.
Addresses issues related to battery and mains power supply.
Details faults specific to wireless devices like low battery or jamming.
Explains common errors during the setting procedure and their solutions.