EURO 46 V10 Programming Manual
Entry/Exit Keypads Only
If this function is disabled, any entry and exit tones will be heard through the main sounder. If
enabled, the entry and exit tones will only be heard through the keypad speaker.
Alert Kps Only
If this function is enabled, any ‘Alert’ tones will be heard on the keypad only and not the main
sounder. If disabled, the alert tones will heard through both.
Silent Technical Alert
If this function is enabled then any technical alerts will be silenced, such as: line fault, ARC call fail.
System Options?
Site Options
Option Description
Set With Fault
If ‘Yes’, the panel will set regardless of the following faults being present:
Device fail, mains fail, battery fault, fuse fault, SMS failure, relay sirens 1&2 or relay strobe faults.
Set With Tamper
If ‘Yes’, the panel will set regardless of the following tamper faults being present:
Case tamper and any system tampers.
Set With ATS Fault
If ‘Yes’, the panel will set regardless of the following ATS faults being present: Telecom line fail,
modem fail, STU/ATE line fault, STU/ATE one path fail, Digi dial fail, or STU/ATE Comms fail.
Set Ward Tech Fault If ‘Yes’ a ward can set even if mains, battery, Comms, or other system faults are present.
Set Fail = Alarm
If ‘Yes’ a graduated alarm will be generated when the ‘Set Fail’ timer expires. If an exit procedure is
still incomplete then the set fail output will trigger too. If ‘No’ the ‘Exit Time’ will continue until the exit
door is closed and the system will return to unset mode at the end of the ‘Set Fail Warning’ time if
programmed.
Do Battery Load Test If ‘Yes’ the system will perform a full load test of the battery at 7:00am each day.
Strobe/Squawk at Set
If set to 'Strobe', any output programmed as ‘Strobe any’ will activate for five seconds after the
control panel has fully set. If ‘Squawk’ is selected, any output programmed as ‘Siren any’ will activate
for five seconds after the panel has set. Finally if set to 'Both' any outputs programmed as ‘Strobe
any’ or ‘Siren any’ will activate for five seconds after the panel has fully set.
PLEASE NOTE: If this function is enabled, a potential security risk could be in view for intruders to
see.
Re-Arm Omits
If ‘Yes’ when the panel rearms at the end of the confirmation time, this function will force an input
(not a system tamper) causing the unconfirmed alarm to be omitted, whether it’s still in fault or not.
Use Level Set
If ‘Yes’, the system becomes ‘level set’ (having one area set only at any one time). If ‘No’: The system
becomes an ‘area’ system (fully independent areas).
Confirmed When
Final Set: Confirmed signal only available after the system is set.
Exit Starts: Confirmed signal available after the exit time has started.
PLEASE NOTE: ‘Exit starts’ is not compliant with BS8243.
PLEASE NOTE: ‘Exit Starts’ must be selected in order for it to be entered in the logs.
Autoset Force If ‘Yes’ when auto-set is in use the panel will still set even if an input is open at the time.
Restrict PIN Use
If ‘Yes’ the system prevents a pin code being entered on the ‘Entry Time’, but allows the system to
be silenced and unset once in alarm.
PLEASE NOTE: Enable when BS8243 option 6.4.5 is in use.
Simple Set
If ‘Yes’, the control panel allows a user to set the system ‘quickly’ by pressing and then the
Area (0, 1, A, B, C or D).
PLEASE NOTE: This must not be enabled when BS8243 option 6.4.5 is in use.
Intelligent Set
When enabled, the panel will set in level set ‘B’ (the user code used must have level sets A and B
assigned), but if a final exit input is activated (such as a front door) on level set ‘A’, the panel will
automatically switch to setting level set ‘A’. If no input is activated, the panel will just set level set ‘B’.
Invert ATE Outputs If ‘Yes’ the outputs are positive removed. If ‘No’ the outputs are positive applied.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION Pyronix EURO 46 V10 and is the answer not in the manual?

HIKVISION Pyronix EURO 46 V10 Specifications

General IconGeneral
BrandHIKVISION
ModelPyronix EURO 46 V10
CategorySecurity System
LanguageEnglish

Related product manuals