EURO 46 V10 Programming Manual
Fault Description Solution
KEYS LOCKED OUT a) More than one device is connected at the same
address.
b) Too many incorrect key presses have been
entered to create a ‘Code Guessing’ condition.
a) Ensure correct addressing so that there are no
overlaps. Next, power the system down and back
up again to correctly reinitialise.
b) Wait 90 seconds for the keypad to be re-
introduced onto the system.
Authorisation
Required
The master manager will need to give the Engineer
access
The option ‘Allow Engineer Menu’ will need to be
enabled by the master manager
Detection Faults
Fault Description Solution
CASE TAMPER Case tamper switch open Ensure the switch is closed
Code Guessing Up to 13 invalid key presses have been entered or
three invalid tags have been presented.
Press the ‘NO’ key to clear.
Power Supply Problems
Fault Description Solution
BATTERY FAULT
xxx
Battery not present or Battery volts low Note: This indication should be expected during
recharge after a mains failure.
BAT LOAD FAIL Battery Load Test has failed Only displays if the option is selected. If the battery is
uncharged or the capacity is below specification, then
it may need replacing.
BAT CRITICAL Battery being disconnected Protects the battery from deep discharge damage
during an extended mains failure.
Note: The system is about to be powered down!
MAINS FAIL xxx Mains supply failed The system detects that the mains frequency is out of
specification, as well as voltage. Note: ‘AC FAIL’ timer
operative.
LOW VOLTS xxx Power supply volts low Battery volts below normal ‘battery fault’ level during
a mains failure.
Engineer Indications
Fault Description Solution
Engineer Access
Denied
Access to Engineer menu NOT possible, as system is
not fully unset.
Ensure that ALL areas are unset, using suitable user
codes/tags at the appropriate keypads/readers.
Check Failed
Input xxx
Input in fault on attempting to exit Engineer mode. Applies to 24-hour tamper, or other input types that
would generate an alarm condition if the system were
returned to unset mode. This also applies to tamper
faults on other input types. Check for the fault on
input, or omit it in programming.
Error input Areas
not accessible
An input has been programmed to an area for which
no setting point is valid to unset.
It would be impossible to fully unset the system after
a tamper alarm on that input. Programming must be
adjusted before exiting Engineer mode.
Error some Areas
cannot be unset
Setting points have been programmed so it is
possible to set an area, but not unset it.
Programming must be adjusted before exiting
Engineer mode.
Wireless Faults (If Wireless ZEM installed)
Fault Description Solution
U-01 (xx)
WLs LOW BATT
Low battery on wireless key fob (user) number ‘xx’ Replace the battery on the key fob mentioned.